2010
DOI: 10.1016/j.ijms.2010.03.004
|View full text |Cite
|
Sign up to set email alerts
|

Atmospheric Pressure Corona Discharge Ionisation and Ion Mobility Spectrometry/Mass Spectrometry study of the negative corona discharge in high purity oxygen and oxygen/nitrogen mixtures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
32
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 42 publications
(34 citation statements)
references
References 18 publications
2
32
0
Order By: Relevance
“…However, in 63 Ni source, the reactant ions are dominated by the ions with m/z 32, which is identified as O 2 − and is consistent with the previous study by Waltman et al 41 The ions at m/z 60 were also observed in negative corona discharge source. 42 presented in low ppmv level through the use of 18 O labeled oxygen technique. 43 In our system, the measured concentration of CO 2 in purified air was about 300 ppm by electron impact ionization time-of-flight mass spectrometry, 44 so the ions at m/ z 60 in DANP and UVRI sources are assigned to CO 3 − .…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…However, in 63 Ni source, the reactant ions are dominated by the ions with m/z 32, which is identified as O 2 − and is consistent with the previous study by Waltman et al 41 The ions at m/z 60 were also observed in negative corona discharge source. 42 presented in low ppmv level through the use of 18 O labeled oxygen technique. 43 In our system, the measured concentration of CO 2 in purified air was about 300 ppm by electron impact ionization time-of-flight mass spectrometry, 44 so the ions at m/ z 60 in DANP and UVRI sources are assigned to CO 3 − .…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…The IMS/MS ( Figure 1a) and APCI/MS (Figure 1b) instruments equipped with point to plane corona discharge ion source were described in our previous work [14]. In attempt to reduce the penetration of the neutrals species and radicals formed in the corona discharge into the drift region we used single flow IMS system with gas outlet behind the corona discharge (reverse flow corona discharge).…”
Section: Methodsmentioning
confidence: 99%
“…Within this IMS peak we have detected also ions m/z 60 Da, which we assigned to N 2 O 2 − . We assumed that this ion originates from following process at atmospheric pressure (4) [26] …”
Section: Rdx Detection With Doping By CCLmentioning
confidence: 99%