2000
DOI: 10.1016/s0308-8146(00)00182-5
|View full text |Cite
|
Sign up to set email alerts
|

Atmospheric pressure chemical ionisation mass spectrometry for in vivo analysis of volatile flavour release

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

8
174
0

Year Published

2002
2002
2018
2018

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 221 publications
(182 citation statements)
references
References 27 publications
8
174
0
Order By: Relevance
“…To monitor real-time changes in the concentration in the air of target volatiles, two distinct techniques were developed in the 90s: APCI-MS, ''Atmospheric Pressure Chemical Ionisation -Mass Spectrometry'' (Taylor, Linforth, Harvey, & Blake, 2000) and PTR-MS, ''Proton Transfer Reaction -Mass Spectrometry'' (Lindinger, Hansel, & Jordan, 1998).…”
Section: Dynamic Analysis Of Volatiles In Sensory Interactionsmentioning
confidence: 99%
See 2 more Smart Citations
“…To monitor real-time changes in the concentration in the air of target volatiles, two distinct techniques were developed in the 90s: APCI-MS, ''Atmospheric Pressure Chemical Ionisation -Mass Spectrometry'' (Taylor, Linforth, Harvey, & Blake, 2000) and PTR-MS, ''Proton Transfer Reaction -Mass Spectrometry'' (Lindinger, Hansel, & Jordan, 1998).…”
Section: Dynamic Analysis Of Volatiles In Sensory Interactionsmentioning
confidence: 99%
“…In practice, all the compounds that contribute to the aroma of a real foodstuff can rarely be monitored simultaneously with such technologies. Those that have very low thresholds and lie outside the detection limits cannot be followed (Taylor et al, 2000). In addition, minor fragment ions with the same m/z value, and positional-and stereoisomers with the same molecular formula, remain barely determined (Lindinger et al, 1998; Taylor et al, 2000).…”
Section: Dynamic Analysis Of Volatiles In Sensory Interactionsmentioning
confidence: 99%
See 1 more Smart Citation
“…The main problems encountered when measuring volatile release of food and beverages are the speed of sampling and the sensitivity to detect several compounds at low concentrations 18 . In addition, measurement of temporal changes during product consumption requires a method with good temporal resolution (sampling as low as every 0.01 sec), limited and controlled fragmentation of ions and no interference of normal eating patterns 18 . Atmospheric pressure chemical ionisationmass spectrometry (APCI-MS) is a soft ionisation technique, providing little fragmentation of ions, allowing rapid measurement of volatile compounds in real time 17 .…”
Section: Introductionmentioning
confidence: 99%
“…Atmospheric pressure chemical ionisationmass spectrometry (APCI-MS) is a soft ionisation technique, providing little fragmentation of ions, allowing rapid measurement of volatile compounds in real time 17 . This can be used to study in-vivo volatile release during consumption providing information on retronasal volatile delivery 18 .…”
Section: Introductionmentioning
confidence: 99%