Proceedings of the European Physical Society Conference on High Energy Physics — PoS(EPS-HEP2017) 2017
DOI: 10.22323/1.314.0485
|View full text |Cite
|
Sign up to set email alerts
|

ATLAS Calorimeter: Run 2 performance and Phase-II upgrades

Abstract: The ATLAS detector was designed and built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to 10 34 cm −2 s −1. A Liquid Argon-lead sampling (LAr) calorimeter is employed as electromagnetic and hadronic calorimeters, except in the barrel region, where a scintillator-steel sampling calorimeter (TileCal) is used as hadronic calorimeter. This presentation gives first an overview of the detector operation and data quality, as well as of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 5 publications
0
1
0
Order By: Relevance
“…When doing a bump hunt for B ps , we find about 10 (20) background events for m χ ≈ 80 (150) GeV, if the width of the constructed invariant mass peak is around 10 GeV, coming from the imperfect DLJ energy measurement. Since further improvements on the Run 3 and high luminosity study are expected due to the more control region data and better HCAL resolution [95][96][97], an even better background rejection can be achieved.…”
Section: Displaced Lepton Jet Signalsmentioning
confidence: 99%
“…When doing a bump hunt for B ps , we find about 10 (20) background events for m χ ≈ 80 (150) GeV, if the width of the constructed invariant mass peak is around 10 GeV, coming from the imperfect DLJ energy measurement. Since further improvements on the Run 3 and high luminosity study are expected due to the more control region data and better HCAL resolution [95][96][97], an even better background rejection can be achieved.…”
Section: Displaced Lepton Jet Signalsmentioning
confidence: 99%
“…In contrast, the liquid argon electromagnetic calorimeter's main function is to entrap all electron and photon energy. The pseudo-rapidity ranges of the electromagnetic calorimeters are |η| < 1.475 for the barrel region, and 1.375 < |η| < 3.2 for the end-caps [15]. To account for energy lost in the inner detector, a pre-sampler detector is used over the |η| < 1.8 range [13].…”
Section: Calorimetry and Forward Detectorsmentioning