2023
DOI: 10.1161/jaha.123.029505
|View full text |Cite
|
Sign up to set email alerts
|

Atherosclerosis Burden of Brain‐ and Heart‐Supplying Arteries and the Relationship With Vascular Risk in Patients With Ischemic Stroke

Qi Kong,
Xin Ma,
Luguang Li
et al.

Abstract: Background Atherosclerosis of brain‐ and heart‐supplying arteries (BHAs) are risk indicators for patients with ischemic stroke, but the atherosclerosis burden (AB) of intracranial, cervical, aortic, and coronary arteries in each and in total have not been simultaneously evaluated, and the associations with vascular risk remain unknown. Methods and Results With computed tomography angiography, single‐territory AB was triple ranked on the basis of the num… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 24 publications
(36 reference statements)
0
1
0
Order By: Relevance
“…Using the dual-source 192-slice CT scanner (Somatom Force, Siemens Healthcare, Erlangen, Germany), all combined coronary and cervicocephalic CTAs were conducted out as previously reported ( 19 ). The CTA scans were conducted from the base of the heart to the head cauda-cranially, using an automated kVp and mA (CARE kV and CARE Dose4D, Siemens) with a pitch of 3.2 and a rotation time of 250 ms.…”
Section: Methodsmentioning
confidence: 99%
“…Using the dual-source 192-slice CT scanner (Somatom Force, Siemens Healthcare, Erlangen, Germany), all combined coronary and cervicocephalic CTAs were conducted out as previously reported ( 19 ). The CTA scans were conducted from the base of the heart to the head cauda-cranially, using an automated kVp and mA (CARE kV and CARE Dose4D, Siemens) with a pitch of 3.2 and a rotation time of 250 ms.…”
Section: Methodsmentioning
confidence: 99%
“…All patients underwent simultaneous CTAs of the coronary and craniocervical arteries with a 192-slice dual-source computed tomography (Somatom Force; Siemens, Munich, Germany), as previously reported [18]. Two experienced radiologists who were blinded to the clinical information analyzed all the scanned images independently and provided a consensus interpretation of each conclusion.…”
Section: Assessment Of Atherosclerosis Conditions In Baroreceptor-res...mentioning
confidence: 99%