2008
DOI: 10.1007/s10749-008-0004-0
|View full text |Cite
|
Sign up to set email alerts
|

Asynchronous turbogenerators and compensators as a means of improving the operating capability of the Moscow power system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…When the d-axis excitation mmf is negative, such as F fd3 , the direction of E fd3 is opposite to that of the terminal voltage, and thus the reactive power consumption of the DESC can be increased. Meanwhile, in order to avoid the out-of-step operation of the DESC, the magnitude and direction of the q-axis field current are controlled so that the electromagnetic torque is always positive [19,20].…”
Section: Structure and Excitation Mode Of Descmentioning
confidence: 99%
“…When the d-axis excitation mmf is negative, such as F fd3 , the direction of E fd3 is opposite to that of the terminal voltage, and thus the reactive power consumption of the DESC can be increased. Meanwhile, in order to avoid the out-of-step operation of the DESC, the magnitude and direction of the q-axis field current are controlled so that the electromagnetic torque is always positive [19,20].…”
Section: Structure and Excitation Mode Of Descmentioning
confidence: 99%
“…The above problem of renewable energy power grid can be solved by increasing the number of synchronous generators. The Dual-Excited Synchronous Generator (DESG), which has two sets of field windings, has better stability and reliability than the Traditional Synchronous Generators (TSG) [6][7][8]. The DESG can support more renewable energy integrated to the power grid than the TSG.…”
Section: Introductionmentioning
confidence: 99%
“…The field is con trolled according to the special vector control law; therefore, machines operate stably both in the modes of reactive power generation and consumption, which is unfeasible for synchronous turbogenerators due to the conditions of static and dynamic stability and structural limitations. It is supposed that, if the asyn chronized turbogenerators and asynchronized com pensators are placed in the power system, it becomes possible to flexibly control the modes of operation and the reactive power [1,2].…”
mentioning