2016
DOI: 10.1364/ao.55.001124
|View full text |Cite
|
Sign up to set email alerts
|

Asymmetric Mach–Zehnder interferometers without an interaction window in polymer foils for refractive index sensing

Abstract: We report on the fabrication and characterization of integrated Mach-Zehnder interferometers in polymer foil without an interaction window. The interferometers are based on inverted rib waveguides, which allow single mode behavior even for waveguide widths larger than a few micrometers. The phase change between the two interferometer arms upon a refractive index change of the analyte that serves as the upper cladding is generated by the asymmetricity of the two interferometer arms. A difference of the waveguid… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 29 publications
(13 citation statements)
references
References 16 publications
0
13
0
Order By: Relevance
“…By using a short wavelength laser (450 nm), a large increase in phase shift is realized in comparison to most of previous works [9,14,15,18,21,26,[28][29][30], which operates with a laser above 630 nm. The sensitivity for homogeneous bulk RI sensing of this sensor is comparable to those made by only polymers [9,19,31] or optical fiber [5]. We remark that approaches like coating with high RI dielectrics can be employed to enhance the LoD [14,17].…”
Section: Measurement Of Ethanol-water Mixturementioning
confidence: 88%
See 1 more Smart Citation
“…By using a short wavelength laser (450 nm), a large increase in phase shift is realized in comparison to most of previous works [9,14,15,18,21,26,[28][29][30], which operates with a laser above 630 nm. The sensitivity for homogeneous bulk RI sensing of this sensor is comparable to those made by only polymers [9,19,31] or optical fiber [5]. We remark that approaches like coating with high RI dielectrics can be employed to enhance the LoD [14,17].…”
Section: Measurement Of Ethanol-water Mixturementioning
confidence: 88%
“…Optical waveguides have been widely used as efficient sensors for detection of refractive index (RI) change by probing near the surface region of the sample with the evanescent field [1][2][3][4][5][6][7]. Recently, polymer waveguides have gained much attention owing to their interesting properties including high transparency in the UV-visible range, versatile process-abilities, cost effectiveness, and mechanical flexibility [8][9][10]. Different designs including ring resonators [11][12][13], interferometers [14][15][16][17][18][19] and guided mode resonance filters [20] have been demonstrated.…”
Section: Introductionmentioning
confidence: 99%
“…Single mode behavior can be modified by optimizing the overall core height, the width and depth of the rib groove. 9 The optimized parameters in this design, are 3 µm, 3.5 µm, and 0.6 µm with height, width and depth respectively.…”
Section: Designmentioning
confidence: 99%
“…In 2016, an asymmetric MZI inverted ridge waveguide sensor based on a polymer substrate was designed and fabricated. The prototype showed a detection limit of 3 × 10 −3 refractive index units for homogeneous sensing at a total system length of 9.3 mm and a total waveguide core thickness of 3 μm [23]. In 2017, a polymer-based effective index sensor based on tailored high-index thin films was reported to enhance the sensitivity of asymmetric MZIs [24].…”
Section: Introductionmentioning
confidence: 99%