2017
DOI: 10.1016/j.envres.2017.01.027
|View full text |Cite
|
Sign up to set email alerts
|

Associations between ambient wood smoke and other particulate pollutants and biomarkers of systemic inflammation, coagulation and thrombosis in cardiac patients

Abstract: Background Increased particulate air pollution has been associated with both an increased risk of myocardial infarction (MI) and adverse changes in cardiac biomarkers. Up to 30% of ambient wintertime fine particles (PM2.5) in Rochester, NY are from wood burning. Our study examined associations between ambient levels of a marker of wood smoke (Delta-C) and other particulate air pollutants and biomarkers of inflammation, coagulation and thrombosis. Methods We measured blood concentrations of C-reactive protein… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
36
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 60 publications
(42 citation statements)
references
References 43 publications
(79 reference statements)
5
36
0
1
Order By: Relevance
“…The MicroAeth AE51 (Aethlabs, USA) is a miniaturized, palm-sized aethalometer (Cheng and Lin 2013;Hagler et al 2011) that measures light attenuation (ATN) induced by the accumulation of BC on a filter at a nearinfrared wavelength of 880 nm. In this study, we ignored the possible interference of light-absorbing organic carbon (brown carbon, BrC), because BrC has a weak light absorption at the wavelength of 880 nm (e.g., Kirchstetter, Novakov, and Hobbs 2004).…”
Section: Microaeth Ae51mentioning
confidence: 99%
See 4 more Smart Citations
“…The MicroAeth AE51 (Aethlabs, USA) is a miniaturized, palm-sized aethalometer (Cheng and Lin 2013;Hagler et al 2011) that measures light attenuation (ATN) induced by the accumulation of BC on a filter at a nearinfrared wavelength of 880 nm. In this study, we ignored the possible interference of light-absorbing organic carbon (brown carbon, BrC), because BrC has a weak light absorption at the wavelength of 880 nm (e.g., Kirchstetter, Novakov, and Hobbs 2004).…”
Section: Microaeth Ae51mentioning
confidence: 99%
“…The AE51 was operated with a Q of 0.2 lpm, a Dt of 1 min, and A was 7.1 mm 2 . Note that, while it should be considered, particle loading correction (Virkkula et al 2007;Weingartner et al 2003) is not typically included during data processing (Cheng and Lin 2013). Therefore, we evaluated this effect using ATN (hereafter referred to as ATN AE51 ) based on intercomparison experiments.…”
Section: Microaeth Ae51mentioning
confidence: 99%
See 3 more Smart Citations