2013
DOI: 10.1016/j.diabres.2013.03.032
|View full text |Cite
|
Sign up to set email alerts
|

Association of automated carotid IMT measurement and HbA1c in Japanese patients with coronary artery disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2015
2015
2017
2017

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 30 publications
(21 citation statements)
references
References 41 publications
0
21
0
Order By: Relevance
“…The system was capable of measuring cIMT ranging up to a 2.0 to 2.5 mm thickness (heavy plaque in the distal wall) based on advanced scale-space methods as developed by Suri's team. 3,11,13,58,59,60,54 In this study we have compared our proposed…”
Section: Benchmarking Atherocloud™ Against Atheroedge™mentioning
confidence: 95%
See 2 more Smart Citations
“…The system was capable of measuring cIMT ranging up to a 2.0 to 2.5 mm thickness (heavy plaque in the distal wall) based on advanced scale-space methods as developed by Suri's team. 3,11,13,58,59,60,54 In this study we have compared our proposed…”
Section: Benchmarking Atherocloud™ Against Atheroedge™mentioning
confidence: 95%
“…Even though there are automated desktop-based intelligent cIMT systems by Suri (PI of this project) and his team, 9,11,13,14,30,48,49 this study is the first of its kind in which cIMT is measured in carotid ultrasound scans through intelligent cloud-computing, with automated analysis occurring in the cloud-based settings. The workflow is shown in Figure. 3.…”
Section: Work Flow Architecture Of Atherocloud™ 10 Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…The phenomenon suggests that in atherosclerotic human coronary arteries, lumen area remained constant until the percent stenosis exceeded 40% [28]. Saba L et al, evaluated the association of automated cIMT with HbA1c for CAD in a Japanese cohort [29]. An analysis was done on 370 patients and results clearly established a direct correlation (p=0.0007) between HbA1c and automated cIMT measurements.…”
Section: Discussionmentioning
confidence: 99%
“…Recently Saba et al [45] has performed a comparative study of correlation between the carotid inter-adventitial diameter (IAD)/LD and the plaque score to predict the risk of stroke. Even though the plaque score has been correlated to IMT before [46], the novelty in this paper is the correlation of LD with the plaque score. The study by Saba et al [45] used the scale-space based automated lumen diameter measurement system to accurately measure the carotid LD/IAD.…”
Section: Automated Systemmentioning
confidence: 98%