2020
DOI: 10.1111/ijlh.13234
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of time‐dependent white blood cells degeneration induced by blood storage on automated parameters and morphology examination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 10 publications
1
3
0
Order By: Relevance
“…Consistent with previous reports in other species, 5,20 a significant increase in neutrophil nuclear area indicative of nuclear swelling was found as canine blood samples aged. This occurred irrespective of storage temperature or inflammatory leukogram status.…”
Section: Discussionsupporting
confidence: 92%
See 1 more Smart Citation
“…Consistent with previous reports in other species, 5,20 a significant increase in neutrophil nuclear area indicative of nuclear swelling was found as canine blood samples aged. This occurred irrespective of storage temperature or inflammatory leukogram status.…”
Section: Discussionsupporting
confidence: 92%
“…Previous studies have shown that cellular deterioration begins within the first 4 h of sample collection, 5,8 and moderate morphologic and hematologic parameter changes are often seen within 48 h. 4,5,7,20 In the present study, a 72-h time point was also included in view of variable transit times of samples received by diagnostic laboratories. This aimed to include the typical sample transit time, as well as accounting for potential delays.…”
Section: Discussionmentioning
confidence: 99%
“…Comprehensive cell population data (CPD) for subpopulations of WBC are possible with the automatic blood cell analyzer DxH800 (Coulter Inc), and this has been applied, for instance, to study WBC changes due to acute bacterial infections, G‐CSF administration, presence of CD34‐positive cells in peripheral blood, degeneration induced by storage and, recently, for COVID‐19 diagnostic workup 4‐8 …”
Section: Introductionmentioning
confidence: 99%
“…3 Comprehensive cell population data (CPD) for subpopulations of WBC are possible with the automatic blood cell analyzer DxH800 (Coulter Inc), and this has been applied, for instance, to study WBC changes due to acute bacterial infections, G-CSF administration, presence of CD34-positive cells in peripheral blood, degeneration induced by storage and, recently, for COVID-19 diagnostic workup. [4][5][6][7][8] The aim of this study was to analyze COVID-19-related abnormalities of WBC and CPD at disease onset, and identify parameters capable of discriminating between severe and nonsevere forms, as well as those with high or low risk of mortality.…”
mentioning
confidence: 99%