2019
DOI: 10.3906/sag-1906-14
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of the visual pathways in patients with neurofibromatosis-1 by 3d-space technique at 3-tesla

Abstract: Background/aim: We aimed to evaluate the size/tortuosity of the optic nerve (ON) and the dilatation of the ON sheath (ONS) in neurofibromatosis type 1 (NF-1) patients with 3T-MRI, and to assess the usefulness of 3D-SPACE in imaging the optic pathway, ON, and ONS in NF-1 patients. Materials and methods: Twenty consecutive NF-1 patients without optic pathway glioma (OPG) (Group 1), 16 consecutive NF-1 patients with OPG (Group 2), and 19 controls were included in this study. The thickness and tortuosity of the ON… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 19 publications
(55 reference statements)
0
1
0
Order By: Relevance
“…3D-T1W turbo spin-echo technique (also called 3D-SPACE or 3D sampling perfection and application-optimized contrasts using the different flip-angle evolutions) was recently introduced for high-field MR units since they offer high-resolution isotropic data with various image contrasts and low specific absorption rate values for the whole cranium within a short time [ 3 ]. Isotropic 3D-SPACE acquisitions facilitate multiplanar, oblique, and/or freehand curved reconstructions to better evaluate the contrast-media leakages and intracranial complex lesions/structures [ 4 ]. 3D-T1W-SPACE and 3D-VIBE sequences have higher contrast-to-noise ratios and visual conspicuity ratings compared with 3D-MPRAGE [ 5 ].…”
Section: Introductionmentioning
confidence: 99%
“…3D-T1W turbo spin-echo technique (also called 3D-SPACE or 3D sampling perfection and application-optimized contrasts using the different flip-angle evolutions) was recently introduced for high-field MR units since they offer high-resolution isotropic data with various image contrasts and low specific absorption rate values for the whole cranium within a short time [ 3 ]. Isotropic 3D-SPACE acquisitions facilitate multiplanar, oblique, and/or freehand curved reconstructions to better evaluate the contrast-media leakages and intracranial complex lesions/structures [ 4 ]. 3D-T1W-SPACE and 3D-VIBE sequences have higher contrast-to-noise ratios and visual conspicuity ratings compared with 3D-MPRAGE [ 5 ].…”
Section: Introductionmentioning
confidence: 99%