2015
DOI: 10.1088/0026-1394/52/3/s97
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of the uncertainty budget associated with 4πγcounting

Abstract: The 4πγ-counting technique is recognized as a powerful primary method for the standardization of radionuclides decaying with abundant gamma emissions. Based on the use of a gamma detector in quasi 4π-geometry, a detection efficiency close to 100% and a low uncertainty can be achieved thanks to the summing effect of subsequent gamma transitions. Uncertainties have to be assigned to the realistic modelling of the source-detector geometry with respect to dimensions, density and material composition, the calculati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 31 publications
0
10
0
Order By: Relevance
“…The measurement techniques employed are as follows: ionisation current measurements in a re-entrant ionisation chamber (IC) or a hospital calibrator (HIC) [31,32], net area analysis of full-energy γ-ray peaks (and integral spectrum counting) by γ-ray spectrometry with a HPGe detector (HPGe) [33], particle counting in a planar silicon detector in quasi-2πconfiguration (PIPS) [34], X-ray counting at a small defined solid angle with a gas-filled proportional counter (PC) [35,36], live-timed β–γ anti-coincidence counting (LTAC) [37], triple-to-double coincidence counting with a liquid scintillation vial and three photodetectors (TDCR) [38], liquid scintillation counting (LSC) [38], particle and photon counting in a sandwich CsI (Tl) spectrometer (CsI) [39], internal gas counting (IGC) [40], and α-particle counting at a small defined solid angle with a large planar silicon detector (αDSA) [35,36]. An overview of standardisation techniques and their sources of error can be found in the special issues 44(4) and 52(3) of Metrologia [41,42] and references in [25,28].…”
Section: Measurements and Analysismentioning
confidence: 99%
“…The measurement techniques employed are as follows: ionisation current measurements in a re-entrant ionisation chamber (IC) or a hospital calibrator (HIC) [31,32], net area analysis of full-energy γ-ray peaks (and integral spectrum counting) by γ-ray spectrometry with a HPGe detector (HPGe) [33], particle counting in a planar silicon detector in quasi-2πconfiguration (PIPS) [34], X-ray counting at a small defined solid angle with a gas-filled proportional counter (PC) [35,36], live-timed β–γ anti-coincidence counting (LTAC) [37], triple-to-double coincidence counting with a liquid scintillation vial and three photodetectors (TDCR) [38], liquid scintillation counting (LSC) [38], particle and photon counting in a sandwich CsI (Tl) spectrometer (CsI) [39], internal gas counting (IGC) [40], and α-particle counting at a small defined solid angle with a large planar silicon detector (αDSA) [35,36]. An overview of standardisation techniques and their sources of error can be found in the special issues 44(4) and 52(3) of Metrologia [41,42] and references in [25,28].…”
Section: Measurements and Analysismentioning
confidence: 99%
“…Monte Carlo (MC) simulations are frequently used to model various aspects of the measurement process [46]. General purpose particle transfer codes [14][15][16][17][18] can reproduce physical processes in customer designed geometries, which has important applications such as the calculation of detection efficiency of a radioactive source in gamma spectrometers [47], ionisation chambers [48] and various other set-ups [49][50][51][52]. Additionally, detailed analytical models have been developed for specific applications, such as efficiency calculations in liquid scintillation counting [51], high-geometry 4πγ counters [52] and defined solid angle counters [53].…”
Section: Monte Carlo Simulations and Analytical Modelsmentioning
confidence: 99%
“…Most of the counterevidence, on the other hand, was performed by experienced metrologists using superior detection techniques and showing awareness of the vulnerability of detector stability to external factors. This is witnessed by dedicated literature discussing factors contributing to the uncertainty budget for primary and secondary standardisation techniques [55][56][57][58][59][60][61][62].…”
Section: Introductionmentioning
confidence: 99%