2019
DOI: 10.1088/1757-899x/471/5/052063
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of The Effectiveness of Secondary Horizontal Insulation Against Rising Damp Performed by Chemical Injection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 1 publication
0
9
0
Order By: Relevance
“…After a period necessary for the mortar to reach full strength, it was subjected to dampening, placing the moulds in a tray with water (on a grate) so that the samples were constantly submerged in approximately 10 mm. After two days, the moulds were taken out of the water, wrapped in foil and left for two weeks in order to ensure even distribution of moisture in the mortar (Monczynski, 2019) (Figure 1).…”
Section: Methodsmentioning
confidence: 99%
“…After a period necessary for the mortar to reach full strength, it was subjected to dampening, placing the moulds in a tray with water (on a grate) so that the samples were constantly submerged in approximately 10 mm. After two days, the moulds were taken out of the water, wrapped in foil and left for two weeks in order to ensure even distribution of moisture in the mortar (Monczynski, 2019) (Figure 1).…”
Section: Methodsmentioning
confidence: 99%
“…These failures or disasters are related to design or execution errors as well as improper use. Additionally, buildings deteriorate due to the use of poor-quality materials, inadequate insulation [27], or a lack of regular repairs and ongoing maintenance ( Figure 3) [28,29].…”
Section: Introductionmentioning
confidence: 99%
“…The ability of the invading injection fluid to displace water already present in the pores was investigated, for both water-based and solvent-based fluids, in the Seventies and Eighties [12,[15][16]. Afterwards, different aspects of this problem and, more in general, the effectiveness of damp-proofing injection products were investigated in laboratory by different researchers, who performed tests on single materials (brick, mortar) [12-13, 17-19, 20], small-size masonry blocks [15,16,18,21], or realscale walls [11,[22][23][24][25]. Some papers also reported on the drying effect of chemical injections onsite, in real buildings affected by rising damp [26][27][28][29][30].…”
Section: Introductionmentioning