Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method

Abstract: The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT imag… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…However, because the present study aimed to analyse the TR (FWHM) of the TSP, these result may not sufficiently reflect the overall temporal element in CT images. Therefore, although the detailed relation between the TSP shape and image quality has to be considered as a function of temporal modulation transfer, which was calculated by Fourier transformation of the TSP [11], characterization of the temporal property of the TSP was partly possible using the index of FWHM in our TR measurement.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, because the present study aimed to analyse the TR (FWHM) of the TSP, these result may not sufficiently reflect the overall temporal element in CT images. Therefore, although the detailed relation between the TSP shape and image quality has to be considered as a function of temporal modulation transfer, which was calculated by Fourier transformation of the TSP [11], characterization of the temporal property of the TSP was partly possible using the index of FWHM in our TR measurement.…”
Section: Discussionmentioning
confidence: 99%
“…In our previous report [11], we proposed a practical method to measure the TR using the impulse method, in which a temporal impulse signal is generated by a small metal ball passing through a gantry rotation plane at a very high speed during the respective scan. The passage of the small metal ball can generate a temporal impulse signal into the projection data.…”
Section: Measurement Principle Of the Impulse Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The images were reconstructed to 0.2-mm-interval images. 2,15 Limited cone beam computed tomography. All patients were subjected to LCBCT (PSR 9000N; Asahi Roentgen, Kyoto, Japan).…”
Section: Ethical Consideration and Consent To Participatementioning
confidence: 99%