Assessment of Spontaneous Neuronal ActivityIn VitroUsing Multi-Well Multi-Electrode Arrays: Implications for Assay Development

Abstract: Multi-electrode arrays (MEAs) are being more widely used by researchers as an instrument platform for monitoring prolonged, non-destructive recordings of spontaneously firing neurons in vitro for applications in modeling Alzheimer's, Parkinson's, schizophrenia, and many other diseases of the human CNS. With the more widespread use of these instruments, there is a need to examine the prior art of studies utilizing MEAs and delineate best practices for data acquisition and analysis to avoid errors in interpretat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
43
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2
2

Relationship

0
10

Authors

Journals

citations
Cited by 43 publications
(46 citation statements)
references
References 60 publications
2
43
0
Order By: Relevance
“…Signal-to-noise ratio could be improved with enabling and tuning on-chip filtering, and improving Faraday cage shielding. In vitro cultures typically fire with amplitudes between 10 - 40 μV [5, 7, 45]. They demand sensitive recording equipment, as an increase of just a few μV in noise for spikes on the lower end of the spectrum can be considered a non-trivial variable.…”
Section: Discussionmentioning
confidence: 99%
“…Signal-to-noise ratio could be improved with enabling and tuning on-chip filtering, and improving Faraday cage shielding. In vitro cultures typically fire with amplitudes between 10 - 40 μV [5, 7, 45]. They demand sensitive recording equipment, as an increase of just a few μV in noise for spikes on the lower end of the spectrum can be considered a non-trivial variable.…”
Section: Discussionmentioning
confidence: 99%
“…Chili pepper compound capsaicin was added into the system to trigger a sensory response. Fold change was calculated from natural logarithm of firing rate in line with literature (Atmaramani et al, 2020 ; Negri et al, 2020 ). Percent change described in Table 2 is the number of spontaneous firing neurons after treatment minus the number before treatment over number before treatment.…”
Section: Methodsmentioning
confidence: 99%
“…MEAs comprise a platform for monitoring prolonged, non-destructive recordings of spontaneously firing neurons in vitro with applications in neurodegenerative diseases. A MEA system combines a cell culture plate with an embedded array of high- or low-impedance electrodes allowing for parallel detection of local field potentials generated by spontaneous or evoked firing of neurons [ 153 , 154 , 155 ]. The generation of synchronously active neuronal networks depends on sequential developmental processes.…”
Section: Functional Assays For Pd Studies and Drug Screening In Himentioning
confidence: 99%