Assessment of skin irritancy in man by laser Doppler flowmetry

Abstract: It is desirable to use more objective methods than visual scoring for the assessment of skin irritancy reactions. In the present study the blood flow in skin sites exposed to sodium lauryl sulfate (SLS) was recorded by a laser Doppler flowmeter. The irritant was applied to the volar forearm of healthy volunteers in concentrations ranging from 0.001% to 5% under occlusion for 24 h. The test sites were scored visually and the blood flow was recorded at 3 different times: 26 h, 48 h and 72 h after the application… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
25
0
2

Year Published

1988
1988
2000
2000

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 145 publications
(33 citation statements)
references
References 4 publications
3
25
0
2
Order By: Relevance
“…A "perfect" techmque does not yet ex1st, but the combmat10n of several methods may g1ve reliable results. The naked (8) no correlatiOn with stronger reactwns (6,8) good quantification of erythema (17) artifacts could be produced positiomng the probe not helpful unless VIsible erythema IS detectable (20) difficult positionmg on the skm dimmution of edema with pressure more reliable than caliper differentiation withm ? +, + and + + reactwns (24) not all Irritants mcrease TEWL (33) good correlatiOn with SLS (33) sensitive to environmental conditions time consummg (compared to the eyes and fingers) storage of several data recorded by different operators eye still remams the simplest, qmckest and cheapest way to assess skm Irritancy, but LDV can detect mvisible changes of blood flow helpful m evaluatmg doubtful patch test reactiOns.…”
Section: Electncal Measurementsmentioning
confidence: 99%
“…A "perfect" techmque does not yet ex1st, but the combmat10n of several methods may g1ve reliable results. The naked (8) no correlatiOn with stronger reactwns (6,8) good quantification of erythema (17) artifacts could be produced positiomng the probe not helpful unless VIsible erythema IS detectable (20) difficult positionmg on the skm dimmution of edema with pressure more reliable than caliper differentiation withm ? +, + and + + reactwns (24) not all Irritants mcrease TEWL (33) good correlatiOn with SLS (33) sensitive to environmental conditions time consummg (compared to the eyes and fingers) storage of several data recorded by different operators eye still remams the simplest, qmckest and cheapest way to assess skm Irritancy, but LDV can detect mvisible changes of blood flow helpful m evaluatmg doubtful patch test reactiOns.…”
Section: Electncal Measurementsmentioning
confidence: 99%
“…The exposure can indirectly be measured through changes in the skin. Evaporimeters measure the evaporation of water from the skin (5) and laser Doppler flow meters record the blood flow (6,7). In a previous study we used the occursence of oil acne as an indicator of skin exposure to cutting fluids in a workshop (8).…”
mentioning
confidence: 99%
“…The correlation between these effects has not yet been fully established. The use of LDV has proven more accurate than visual scoring in the scaling and differentiation of irritation effects [24][25][26], and it has also been employed to measure the effects of enhancers on the percutaneous absorption of nicotinates [27,28].…”
Section: Introductionmentioning