2018
DOI: 10.1016/j.enbuild.2017.09.069
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of single-family house thermal renovation based on comprehensive on-site diagnostics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 30 publications
(16 citation statements)
references
References 12 publications
0
16
0
Order By: Relevance
“…This type of connection in the described OWT-67 system creates a bringing technical problems linear thermal bridge (structural). The tests of the structural thermal bridge of the prefabricated system of the balcony slab of the system were carried out as a thermographic quality assessment [10,[14][15][16][17].…”
Section: Thermography Diagnosticsmentioning
confidence: 99%
“…This type of connection in the described OWT-67 system creates a bringing technical problems linear thermal bridge (structural). The tests of the structural thermal bridge of the prefabricated system of the balcony slab of the system were carried out as a thermographic quality assessment [10,[14][15][16][17].…”
Section: Thermography Diagnosticsmentioning
confidence: 99%
“…Bad indoor thermal experience accounts for a large proportion of householders' complaints [3]. Consequently, home renovation has become a common choice for improving their indoor thermal environment, which typically includes window replacement, better insulation, installation of a more efficient heating system, and improvements in house airtightness and natural ventilation, using mechanical ventilation systems [4]. However, improvements in thermal indoor environments are hampered by an outmoded renovation design process that fails to efficiently coordinate design aspects (architectural, facilities, structural, and environmental) while problem-solving issues and handling the feedback loop in a timely manner.…”
Section: Introductionmentioning
confidence: 99%
“…Each method includes on-site inspection, diagnostic and computational analyses. The final stage of the 3-year project has focused on the practical application and validation of developed methodology in real buildings, described in detail in the published Handbook Vol.5 [7] and presented in scientific/research articles [8,9,10,11,12]. This paper presents the insights on a comprehensive on-site diagnostics based on an exemplary multi-family building.…”
Section: Introductionmentioning
confidence: 99%