2005
DOI: 10.1016/j.healun.2005.05.016
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Recurrent Heart Failure Associated with Left Ventricular Assist Device Dysfunction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
10
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 19 publications
0
10
0
Order By: Relevance
“…It is known that functional recovery from heart failure can be achieved through mechanical unloading using LVADs; however, the rate of recovery sufficient to allow explantation of the device is usually low and the incidence of recurrent failure is high. [1][2][3] In an attempt to increase both the rate and durability of recovery a combination therapy protocol was developed at our center. This protocol combines LVAD support with a pharmacologic regime that initially maximizes unloading-induced reverse remodeling and then stimulates physiologic cardiac hypertrophy and improves cardiac function.…”
mentioning
confidence: 99%
“…It is known that functional recovery from heart failure can be achieved through mechanical unloading using LVADs; however, the rate of recovery sufficient to allow explantation of the device is usually low and the incidence of recurrent failure is high. [1][2][3] In an attempt to increase both the rate and durability of recovery a combination therapy protocol was developed at our center. This protocol combines LVAD support with a pharmacologic regime that initially maximizes unloading-induced reverse remodeling and then stimulates physiologic cardiac hypertrophy and improves cardiac function.…”
mentioning
confidence: 99%
“…Small studies evaluating displacement-pump LVADs showed that kinks or obstruction of the inflow or outflow cannula occurred in 7% to 50% of LVAD patients with heart failure [16,17]. Although data in continuous-flow LVADs are lacking, the left ventricular myocardium may obstruct the inflow cannula after improper surgical placement, migration, or ventricular remodeling (Fig.…”
Section: Cannulaementioning
confidence: 99%
“…Patients who have an existing prosthetic valve and require LVAD support also present a management dilemma because of their increased risk of thromboembolism during periods when series flow conditions are episodically replaced with parallel conditions through the native outflow tract. 7 Historically, uncorrected moderate or greater aortic insufficiency and/or a pre-existing prosthetic aortic valve were considered contraindications to LVAD support. However, successful aortic valve closure at the time of LVAD implant has been reported without untoward effects.…”
mentioning
confidence: 99%