2004
DOI: 10.1016/j.brachy.2004.02.002
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of radiation safety instructions to patients based on measured dose rates following prostate brachytherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
13
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 24 publications
(16 citation statements)
references
References 4 publications
3
13
0
Order By: Relevance
“…Now some publications are available which provide interesting and important data on radiation protection for 125 I and 103 Pd permanent implants. These data [2,3,6,8,10,18] support the conclusion that patients treated with these implants do not represent a radiation risk to members of the public. As regards family members and close friends or carers, it must be taken into account, however, that for these persons there may result dose rate values -due to smaller distances and considerably longer periods of contact -that lead to radiation exposures exceeding, e.g., 1 mSv per calendar year [2,7,8].…”
Section: Methodssupporting
confidence: 71%
“…Now some publications are available which provide interesting and important data on radiation protection for 125 I and 103 Pd permanent implants. These data [2,3,6,8,10,18] support the conclusion that patients treated with these implants do not represent a radiation risk to members of the public. As regards family members and close friends or carers, it must be taken into account, however, that for these persons there may result dose rate values -due to smaller distances and considerably longer periods of contact -that lead to radiation exposures exceeding, e.g., 1 mSv per calendar year [2,7,8].…”
Section: Methodssupporting
confidence: 71%
“…The safety of LDR prostate brachytherapy has been investigated in several studies (13)(14)(15), and the radiation dose emitted from the implanted seeds was shown to be negligible as far as exposure of the general public to radiation was a concern (13,14). Applying the current NRC tissue-weighting factor of 0.25 for the gonads (as a surrogate for penile tissues) to the 5 mSv, the whole body effective dose limit, results in an equivalent organ dose limit for the penile tissue of 20 mGy (2 cGy).…”
Section: Discussionmentioning
confidence: 99%
“…Published data from direct dose measurements from patients differ by more than a factor of 10 and show a large variation. In this report data from MSKCC [84] of a person present in the isotropic beam of radiation at some distance from the patient, a conversion factor of 0.05 Sv/Gy is handled [85].…”
Section: A3 Safety Aspectsmentioning
confidence: 99%