1985
DOI: 10.1109/tns.1985.4336867
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Present and Future Large-Scale Semiconductor Detector Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2003
2003
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(11 citation statements)
references
References 27 publications
(20 reference statements)
0
11
0
Order By: Relevance
“…Therefore, the results of measurement with the Timepix device are also valid for the Medipix2. The two important conclusions of the experimental studies were that the charge spread can be described with a 2D Gaussian distribution [14], which was in fact just a con¿rmation of theory [15] and other experimental evaluations [10]. The second important conclusion was that the width of the Gaussian, and therefore also the cluster 1 size, as discussed in [12], was changing almost linearly with the depth of photon interaction.…”
Section: Charge Sharingmentioning
confidence: 60%
See 1 more Smart Citation
“…Therefore, the results of measurement with the Timepix device are also valid for the Medipix2. The two important conclusions of the experimental studies were that the charge spread can be described with a 2D Gaussian distribution [14], which was in fact just a con¿rmation of theory [15] and other experimental evaluations [10]. The second important conclusion was that the width of the Gaussian, and therefore also the cluster 1 size, as discussed in [12], was changing almost linearly with the depth of photon interaction.…”
Section: Charge Sharingmentioning
confidence: 60%
“…The charge collection in a pixelated silicon sensor was extensively studied with the Timepix detector [12], [13], [15]. The Timepix detector is a descendant of the Medipix2 device.…”
Section: Charge Sharingmentioning
confidence: 99%
“…This indicates that working in over-depletion mode reduces charge sharing [114], [115]. Going below full depletion (17 V detector bias), the SNR decreased to ~19.…”
Section: Systematic Pixel-to-pixel Variationsmentioning
confidence: 98%
“…5). The transverse diffusion of drifting charge carriers was modelled by projecting released charge carriers to the pixel electrode plane using a probability density function whose width depended on the point of generation of each free charge carrier [9]. Additionally, Coulomb repulsion in the charge carrier cloud was taken into account by an enlarged effective diffusion constant.…”
Section: Simulationmentioning
confidence: 99%