Assessment of Patient Exposure to X-Radiation from SPECT/CT Scanners

Abstract: In the operation of any SPECT/CT system, in addition to internal radiation exposure (g-ray) resulting from administration of radiopharmaceuticals, external radiation exposure (x-ray) from the CT device has to be taken into consideration in the light of recommendations from the International Commission on Radiological Protection. These recommendations include justification of practices (the use of radiation produces sufficient benefit to offset any risks caused by the use of radiation), optimization (the incurr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
3
0
2

Year Published

2012
2012
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 10 publications
(7 reference statements)
1
3
0
2
Order By: Relevance
“…Der Beitrag der Strahlenexposition durch die CT-Komponente zu der Gesamtexposition einer Neuro-SPECT/CT-Untersuchung kann in Abhängigkeit der Akquisitionsparameter (kVp, mAs) stark variieren [ 8 ] .…”
Section: Neuro-spect/ctunclassified
“…Der Beitrag der Strahlenexposition durch die CT-Komponente zu der Gesamtexposition einer Neuro-SPECT/CT-Untersuchung kann in Abhängigkeit der Akquisitionsparameter (kVp, mAs) stark variieren [ 8 ] .…”
Section: Neuro-spect/ctunclassified
“…The early use of CT in combination with SPECT was aimed at attenuation correction and consisted of a CT component with fixed acquisition parameters. These scanner types are frequently referred to as low dose, with an effective dose 80%-85% lower than diagnostic quality CT scans [11][12][13][14]. Diagnostic CT (DCT) can be used to aid diagnosis rather than correcting the emission data alone [15] and can also provide localization data [16].…”
Section: Introductionmentioning
confidence: 99%
“…The additional dose from the CT component of SPECT-CT has been investigated [11][12][13][14]. Larkin et al [13], Sharma et al [11], and Montes et al [14] use the dose length product and conversion (k) factors to calculate effective dose.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…1 L'acquisition de la technologie TEP est programmée dans la foulée pour 2013. L'imagerie hybride TEMP/TDM et TEP/ TDM va se généraliser rapidement et devenir un examen de routine, c'est pourquoi la sensibilisation des médecins et des techniciens à la notion de dosimétrie additionnelle est une priorité au même titre que la notion de contrôle qualité de ces nouveaux équipements ou la notion d'assurance qualité en imagerie moléculaire multimodale, étant donné qu'avec ces appareils hybrides l'irradiation du patient n'est plus seulement liée aux produits radiopharmaceutiques administrés, mais aussi à la composante scanographique [1][2][3][4].…”
Section: Introductionunclassified