2023
DOI: 10.1016/j.clae.2021.101571
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of meibomian gland drop-out and visibility through a new quantitative method in scleral lens wearers: A one-year follow-up study

Abstract: To validate a previously developed algorithm based on the visibility of meibomian gland images obtained with Cobra fundus camera and to assess the changes in meibomian glands in scleral lens wearers over one year of lens wear. Methods: Infrared meibography was obtained from the upper eyelid using the Cobra fundus camera in forty-three volunteers (34.2 ± 10.1 years). Meibographies were classified into 3 groups: Group 1 = good subjective gland visibility and gland drop-out < 1/3 of the total area; Group 2 = low … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 65 publications
0
2
0
Order By: Relevance
“…Alternatively, the Cobra HD (http://csoitalia.it) nonmydriatic digital fundus camera 11 uses Phoenix semi‐automated software, which is specially designed for MG analysis 14 and employs a ‘vectorised’ tool with Beziers curves that adapt rapidly to the eyelid shape 12 . Thus, the Phoenix semi‐automated software is both quicker and better than the rough segmentation obtained with ImageJ free‐hand selection 12 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Alternatively, the Cobra HD (http://csoitalia.it) nonmydriatic digital fundus camera 11 uses Phoenix semi‐automated software, which is specially designed for MG analysis 14 and employs a ‘vectorised’ tool with Beziers curves that adapt rapidly to the eyelid shape 12 . Thus, the Phoenix semi‐automated software is both quicker and better than the rough segmentation obtained with ImageJ free‐hand selection 12 .…”
Section: Introductionmentioning
confidence: 99%
“…11 Despite this, the OCULUS Keratograph 5 M has been reported to have good interexaminer reproducibility (IER; mean difference between examiners of 0.08 ± 0.55 and 0.13 ± 0.50 grade units in two separate sessions, respectively) with low within-subject variability (WSV; 95% limits of agreement for two different examiners of −1.02 to +1.10 and −1.27 to +1.09 grade units, respectively). 13 Alternatively, the Cobra HD (csoit alia.it) nonmydriatic digital fundus camera 11 uses Phoenix semi-automated software, which is specially designed for MG analysis 14 and employs a 'vectorised' tool with Beziers curves that adapt rapidly to the eyelid shape. 12 Thus, the Phoenix semi-automated software is both quicker and better than the rough segmentation obtained with ImageJ free-hand selection.…”
Section: Introductionmentioning
confidence: 99%
“…[7] Despite this, the OCULUS Keratograph 5M has been reported to have good inter-examiner reproducibility (IER; mean difference between examiners of 0.08± 0.55 and 0.13 ± 0.50 grade units in two separate sessions, respectively) with low within-subject variability (WSV; 95% limits of agreement for two different examiners of −1.02 to +1.10 and −1.27 to +1.09 grade units, respectively). [2] Alternatively, the Cobra HD (csoitalia.it) nonmydriatic digital fundus camera [7] uses Phoenix semi-automated software, which is specially designed for MG analysis [8] and employs a 'vectorised' tool with Beziers curves that adapt rapidly to the eyelid shape. [9] Thus, the Phoenix semiautomated software is both quicker and better than the rough segmentation obtained with ImageJ free-hand selection.…”
Section: Meibographymentioning
confidence: 99%
“…The Cobra HD (csoitalia.it) non-mydriatic digital fundus camera [7] with Phoenix semi-automated software that is specially designed for MG analysis, [8] employs a 'vectorised' tool with Beziers curves that adapts rapidly to the eyelid shape. [9] The Phoenix software requires that the examiner mark the area of the eyelids and the location where the glands are observed, while the software subsequently calculates the percentage of MG loss.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation