Assessment of light transmission aggregometry on the routine coagulation analyzer Sysmex CS-2500 using CE-marked agonists from Hyphen Biomed

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…With both LTA and release assays, single agonist abnormalities are usually a false positive and are much less predictive of a bleeding disorder than multiple agonist abnormalities . Some laboratories perform LTA on automated coagulation analyzers, which appears to provide comparable findings to traditional LTA . Many laboratories incorrectly interpret LTA findings that show normal variants or false positives (eg, reduced MA with a single agonist), and/or fail to consider all potential causes for multiple agonist abnormalities .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…With both LTA and release assays, single agonist abnormalities are usually a false positive and are much less predictive of a bleeding disorder than multiple agonist abnormalities . Some laboratories perform LTA on automated coagulation analyzers, which appears to provide comparable findings to traditional LTA . Many laboratories incorrectly interpret LTA findings that show normal variants or false positives (eg, reduced MA with a single agonist), and/or fail to consider all potential causes for multiple agonist abnormalities .…”
Section: Resultsmentioning
confidence: 99%
“…26,27,31 Some laboratories perform LTA on automated coagulation analyzers, which appears to provide comparable findings to traditional LTA. 32 Many laboratories incorrectly interpret LTA findings that show normal variants or false positives (eg, reduced MA with a single agonist), and/or fail to consider all potential causes for multiple agonist abnormalities. 33 Such errors could be prevented by following guideline recommendations on LTA interpretation.…”
Section: Interpretation Of Platelet Function Tests Performed With Mmentioning
confidence: 99%
“…Furthermore, promising results are accomplished with platelet aggregation studies under flow conditions [28]. Advantages of these new methods are the use of whole blood and low sample preparation, but they also require trained technicians and specialized equipment [29][30][31][32][33][34]. Likewise, standardization of the traditional LTA method is still essential here.…”
Section: Discussionmentioning
confidence: 99%
“…The instrument then carries out automated light transmission aggregometry. In instances where it has been compared head-to-head with traditional light transmission aggregometry ( Table 2 ), the Sysmex CS-2000i has shown repeatability, reproducibility and agreement with traditional aggregometers [ 15 , 16 , 17 , 18 ]. While the technology is certainly advantageous in terms of labour requirement, it still calls for an appreciable volume of platelet-rich plasma (140 µL per test) albeit less than traditional aggregometry (200–500 µL per test) [ 16 ].…”
Section: Light Transmission Aggregometry Revisitedmentioning
confidence: 99%
“…The instrument then carries out automated light transmission aggregometry. In instances where it has been compared head-to-head with traditional light transmission aggregometry (Table 2), the Sysmex CS-2000i has shown repeatability, reproducibility and agreement with traditional aggregometers [15][16][17][18]. While the technology is certainly advantageous in terms of labour…”
Section: Light Transmission Aggregometry Revisitedmentioning
confidence: 99%