2012
DOI: 10.1177/1553350611429689
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Knee Implant Alignment Using Coordinate Measurement on Three-Dimensional Computed Tomography Reconstructions

Abstract: The rapid development of navigation systems designed to improve implant alignment calls for precise methods to verify positioning. One new approach to assess knee implant alignment is coordinate measurement (CM) using reference objects on 3-dimensional reconstructions of computed tomographic (CT) image sequences. The objectives of this study were to determine whether implant alignment can be accurately and precisely examined with CT-based CM, and whether correct positioning of a transversal support implant can… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
8

Relationship

6
2

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 30 publications
0
11
0
Order By: Relevance
“…(Volume Graphics GmbH, Heidelberg, Germany). Surface determination and orientation of the specimens were performed using the method described by Nowakowski et al [15]. The maximum superior-inferior and anterior-posterior distances were determined for each glenoid cavity.…”
Section: Methodsmentioning
confidence: 99%
“…(Volume Graphics GmbH, Heidelberg, Germany). Surface determination and orientation of the specimens were performed using the method described by Nowakowski et al [15]. The maximum superior-inferior and anterior-posterior distances were determined for each glenoid cavity.…”
Section: Methodsmentioning
confidence: 99%
“…We imported the ACR NEMA images in soft‐tissue kernel to on‐display measurement using the image visualization software VGStudio Max 2.1.1 (Volume Graphics GmbH, Heidelberg, Germany). Surface determination and orientation of the specimens were performed using the method described by Nowakowski et al According to Iannotti et al, we measured the radius at 8 points for the glenoid cavity and at 10 points for the humeral head. The maximum superior–inferior and anterior–posterior distances were determined for each glenoid cavity.…”
Section: Methodsmentioning
confidence: 99%
“…(Volume Graphics GmbH, Heidelberg, Germany). Surface determination and orientation of the specimens were performed using the method described by Nowakowski et al [13] and De Wilde et al [4] (Fig. 1a).…”
Section: Cartilage Thickness Measurementmentioning