2008 Computers in Cardiology 2008
DOI: 10.1109/cic.2008.4749144
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of global cardiac function in MSCT imaging using fuzzy connectedness segmentation

Abstract: The goal of this work is to assess global cardiac function in terms of ventricular volume from Multi-Slice Computed Tomography dynamic dataset. We propose an approach for the segmentation of the left ventricle and the measurement of the ventricular volume along the whole cardiac cycle. It is based on the segmentation of the left cavities using a fuzzy connectedness algorithm. The interactive placement of a 3D valvular plane is then used to cut through the segmented surface in order to extract the left ventricl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2009
2009
2015
2015

Publication Types

Select...
4
2
1

Relationship

3
4

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 11 publications
0
3
0
1
Order By: Relevance
“…The slices are chosen due to the presence of outlier segmentations. The different segmentation entries are selected inside a database that contains the results obtained by different research teams [14,15,16,17,18,19] for some parameters which are not necesseraly the optimal ones. The corresponding contours of the different entries are given respectively in Fig.5 for the first slice (denoted by slice 1) and in Fig.7 for the second slice (denoted by slice 2).…”
Section: Cardiac Mr Imagesmentioning
confidence: 99%
“…The slices are chosen due to the presence of outlier segmentations. The different segmentation entries are selected inside a database that contains the results obtained by different research teams [14,15,16,17,18,19] for some parameters which are not necesseraly the optimal ones. The corresponding contours of the different entries are given respectively in Fig.5 for the first slice (denoted by slice 1) and in Fig.7 for the second slice (denoted by slice 2).…”
Section: Cardiac Mr Imagesmentioning
confidence: 99%
“…Combining multi-detector and gantry high rotation speed, Multi-Slice CT (MSCT) allows dynamic cardiac acquisition with a high spatial resolution. In order to segment the left endocardium over the cardiac cycle, we use a segmentation method based on a fuzzy connectedness algorithm [16], the results have been visually validated by a medical expert. The segmented surfaces are then reconstructed.…”
Section: B Ct Data Segmentationmentioning
confidence: 99%
“…Un seuillage choisi par l'utilisateur est appliqué sur cette carte et permet de ne conserver que les structures d'intérêt. Ces méthodes ont montré leur intérêt pour la segmentation du VG en imagerie scanner cardiaque [17]. Dans les méthodes de « graph-cuts » [18], l'utilisateur doit sélectionner deux régions appartenant l'une à l'objet et l'autre au fond pour initialiser une procédure de minimisation d'énergie basée sur un algorithme de coupure de graphe.…”
Section: Introductionunclassified