2015
DOI: 10.1089/lrb.2014.0032
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Breast Cancer-Related Lymphedema: A Comparison of Moisture Meter and Spot Bioimpedance Measurement

Abstract: Both TDC and spot bioimpedance may have a role in clinical assessment of tissue compositional change in BCRL. Their relationship with tissue composition, assessed by imaging, is now required.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 33 publications
(63 reference statements)
1
10
0
Order By: Relevance
“… 35 Further development of both of these measurement techniques and correlation of results with imaging are important before translation into routine clinical practice. 36 On the other hand, water–fat MRI not only detects superficial tissue changes, but also changes in the whole composition of the extremity. Thus, water–fat MRI can possibly be used as a supplement to BIS and TDC in standardizing these methods, and in addition to analyze deep tissue changes before and after treatment.…”
Section: Discussionmentioning
confidence: 99%
“… 35 Further development of both of these measurement techniques and correlation of results with imaging are important before translation into routine clinical practice. 36 On the other hand, water–fat MRI not only detects superficial tissue changes, but also changes in the whole composition of the extremity. Thus, water–fat MRI can possibly be used as a supplement to BIS and TDC in standardizing these methods, and in addition to analyze deep tissue changes before and after treatment.…”
Section: Discussionmentioning
confidence: 99%
“…Perometry, optical assessment of limb volume, is less time-consuming but more expensive. Tonometry is a noninvasive method that can detect subclinical interstitial edema via continuously measuring the dielectric constant in affected tissue and evaluating moisture content (88). BIS is more specific, but lacks sensitivity, and it may be the most frequently utilized modality (71).…”
Section: Diagnosis and Surveillancementioning
confidence: 99%
“…Volume of whole arm = sum of volumes of all segments of arm [22] (see figure 3) Material MoistureMeter D Compact (Delfin Technologies) [24][25][26] Reference points Deltoid, 5cm below lateral border of acromion Side of trunk, 5cm below axillary crease Method If skin is recently hydrated, dehydrate skin Sensor is placed perpendicular on the reference points with a pressure that is indicated by the device High electromagnetic wave is sent through the skin which will only be absorbed by water Degree of reflection/ water content can be read on the display of MoistureMeter D Ratio PWC = PWC healthy side / PWC affected side Change of stagnation of lymph at level of shoulder and trunk = Ratio PWC time 2 -Ratio PWC time 1…”
Section: Reference Pointsmentioning
confidence: 99%