2022
DOI: 10.1016/j.anireprosci.2022.107089
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of an open-access CASA software for bovine and buffalo sperm motility analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 40 publications
(56 reference statements)
0
2
0
Order By: Relevance
“…Flow cytometric data were analysed using FlowJo procedures (FlowJo, LLC, Ashland, OR, USA). Del Prete et al (2022) use the FACSCalibur flow cytometer (Becton Dickinson, Milan, Italy) equipped with a 488 nm argon-ion laser and a 635 nm red diode laser was used in this study with the following filters: 530/30 band-pass (green/ FL-1), 585/42 band-pass (orange/FL-2), > 670 long https://doi.org/10.17221/152/2023-CJAS for assessing plasma membrane damage (Savvulidi et al 2021). Subsequently, sperm samples were analysed using a NovoCyte 3000 digital flow cytometer (Acea Biosciences, part of Agilent, Santa Clara, CA, USA).…”
Section: Evaluation Of Sperm Plasma Membrane Integritymentioning
confidence: 99%
See 1 more Smart Citation
“…Flow cytometric data were analysed using FlowJo procedures (FlowJo, LLC, Ashland, OR, USA). Del Prete et al (2022) use the FACSCalibur flow cytometer (Becton Dickinson, Milan, Italy) equipped with a 488 nm argon-ion laser and a 635 nm red diode laser was used in this study with the following filters: 530/30 band-pass (green/ FL-1), 585/42 band-pass (orange/FL-2), > 670 long https://doi.org/10.17221/152/2023-CJAS for assessing plasma membrane damage (Savvulidi et al 2021). Subsequently, sperm samples were analysed using a NovoCyte 3000 digital flow cytometer (Acea Biosciences, part of Agilent, Santa Clara, CA, USA).…”
Section: Evaluation Of Sperm Plasma Membrane Integritymentioning
confidence: 99%
“…Several methodologies of JC-1 usage were described in recent publications. For instance, flow cytometry analysis with JC-1 was performed to evaluate mitochondrial membrane potential (Ψm) in the study of Del Prete et al (2022). In this study, the FACSCalibur flow cytometer (Becton Dickinson, Milan, Italy) was equipped with a 488 nm argon-ion laser and a 635 nm red diode laser was used with the following filters: 530/30 band-pass (green/FL-1), 585/42 band-pass (orange/FL-2), > 670 long pass (far-red/FL-3) and 661/16 band-pass (orange far red laser/FL-4).…”
Section: Evaluation Of Mitochondrial Statusmentioning
confidence: 99%