Assessment of absorbed dose to thyroid, parotid and ovaries in patients undergoing Gamma Knife radiosurgery

Abstract: Stereotactic radiosurgery was originally introduced by Lars Leksell in 1951. This treatment refers to the noninvasive destruction of an intracranial target localized stereotactically. The purpose of this study was to identify the dose delivered to the parotid, ovaries, testis and thyroid glands during the Gamma Knife radiosurgery procedure. A three-dimensional, anthropomorphic phantom was developed using natural human bone, paraffin and sodium chloride as the equivalent tissue. The phantom consisted of a thora… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(18 citation statements)
references
References 22 publications
0
18
0
Order By: Relevance
“…4 and 5 it can be seen that our system (minidosimeter/K-Band spectrometer) is able to detect doses of the order of 10 Gy, unlike the work of Mack et al [39] whose minimum dose was 150 Gy to obtain an X-Band EPR spectrum with good S/N ratio with an L-alanine minidosimeter. It is important to note that dose values typically found in radiosurgery treatments are 10 Gy [40,41] making our system, a potential candidate to be used in radiosurgery dosimetry.…”
Section: Resultsmentioning
confidence: 99%
“…4 and 5 it can be seen that our system (minidosimeter/K-Band spectrometer) is able to detect doses of the order of 10 Gy, unlike the work of Mack et al [39] whose minimum dose was 150 Gy to obtain an X-Band EPR spectrum with good S/N ratio with an L-alanine minidosimeter. It is important to note that dose values typically found in radiosurgery treatments are 10 Gy [40,41] making our system, a potential candidate to be used in radiosurgery dosimetry.…”
Section: Resultsmentioning
confidence: 99%
“…In order to check the accuracy in dose delivery, a human phantom which had three sections (head and neck, trunk, hip) was used. [13] A 0.3-cc ion chamber (TM31013, PTW-Freiburg) was imbedded in the phantom at the prescribed point (umbilicus) and the delivered dose was measured.…”
Section: Methodsmentioning
confidence: 99%
“…The validity of these algorithms was investigated using the human phantom. [13] Surface doses were measured by diodes and the positioning of these detectors was carefully carried out in order to avoid a shadowing effect. Midplane doses were measured with the 0.3 cc ionization chamber (TM31013).…”
Section: Methodsmentioning
confidence: 99%
“…Hasanzadeh et al . [45] constructed an anthropomorphic phantom and undertook TLD measurements of dose in untargeted organs for Gamma-Knife radiosurgery. Petti et al .…”
Section: Measurement and Calculation Of Out-of-field Dosementioning
confidence: 99%
“…[45] The subplot is a ratio plot of the 6-field CRT and IMRT deliveries compared to the 4-field CRT delivery (monitor units were 1260, 1308 and 2850, respectively). Difference between achieving a 14×14-cm 2 field with a static MLC or with a sliding-window technique [adapted from Sharma et al .…”
Section: Measurement and Calculation Of Out-of-field Dosementioning
confidence: 99%