Assessment of a novel solid oxide fuel cell tri-generation system for building applications

Abstract: 9The paper provides a performance analysis assessment of a novel solid oxide fuel cell 10 (SOFC) liquid desiccant tri-generation system for building applications. The work 11 presented serves to build upon the current literature related to experimental evaluations 12 of SOFC tri-generation systems, particularly in domestic built environment applications. 13The proposed SOFC liquid desiccant tri-generation system will be the first-of-its-kind. No 14 research activity is reported on the integration of SOFC, or a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(11 citation statements)
references
References 36 publications
0
11
0
Order By: Relevance
“…In line with the monitoring and prediction of the system, experimental studies involving the real fuel cell-based cogeneration system is valuable to analyze the durability of the system. A couple of studies that have implemented the cogeneration system for a real implementation can be used as references [109,110]. Since the PEMFC and SOFC are well known as the prime mover in cogeneration systems, the finding of its commercialized products is easier to obtain.…”
Section: Future Directions Of Fuel Cells Application In Energy Generamentioning
confidence: 99%
“…In line with the monitoring and prediction of the system, experimental studies involving the real fuel cell-based cogeneration system is valuable to analyze the durability of the system. A couple of studies that have implemented the cogeneration system for a real implementation can be used as references [109,110]. Since the PEMFC and SOFC are well known as the prime mover in cogeneration systems, the finding of its commercialized products is easier to obtain.…”
Section: Future Directions Of Fuel Cells Application In Energy Generamentioning
confidence: 99%
“…Elmer et al. used empirical SOFC and liquid desiccant component data and provided an energetic, economic, and environmental performance assessment of the combined system. The economic and environmental analysis showed an improvement in SOFC capital cost and the transition to clean hydrogen production.…”
Section: Introductionmentioning
confidence: 99%
“…and the step of substituting the residual building energy demand through energy supply from active technologies (e.g., PV system with ESS) must be adopted. Most of the previous studies, however, were conducted by focusing on only one strategy (i.e., passive or active strategies) [130][131][132][133][134][135][136][137][138][139][140][141][142]. Therefore, an integrated analysis of the energy performance of a building where both passive and active strategies are applied should be performed in the early phase of a building's life cycle from the perspective of achieving nZEB.…”
Section: Integration Of the Passive And Active Strategiesmentioning
confidence: 99%
“…In the previous studies analyzed in Section 2.2.2, most applied DR to analyze energy savings based on historical data [130][131][132][133][134][135][136][137][138][139][140][141][142]. However, in order to effectively manage the building from nZEB perspectives, it is necessary to obtain the energy demands and supply information in real-time.…”
Section: Developing An Integrated Real-time Monitoring System For Buimentioning
confidence: 99%