2020
DOI: 10.1038/s41433-020-1052-4
|View full text |Cite
|
Sign up to set email alerts
|

Assessing visible aerosol generation during vitrectomy in the era of Covid-19

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 6 publications
0
6
0
Order By: Relevance
“…There was no detectable aerosol generation during microkeratome-assisted LASIK and vitrectomy. 52–54 However, experiments on porcine eyes and models of human cadaveric corneoscleral rim mounted on an artificial anterior chamber showed visible aerosol produced during phacoemulsification. 55 , 56 Besides, the studies of Workman et al on human cadaver heads demonstrated that cold instrument and microdebrider use did not generate visible aerosols, but endoscopic endonasal surgery using a high-speed drill and cautery use generated large amounts of aerosols.…”
Section: Resultsmentioning
confidence: 99%
“…There was no detectable aerosol generation during microkeratome-assisted LASIK and vitrectomy. 52–54 However, experiments on porcine eyes and models of human cadaveric corneoscleral rim mounted on an artificial anterior chamber showed visible aerosol produced during phacoemulsification. 55 , 56 Besides, the studies of Workman et al on human cadaver heads demonstrated that cold instrument and microdebrider use did not generate visible aerosols, but endoscopic endonasal surgery using a high-speed drill and cautery use generated large amounts of aerosols.…”
Section: Resultsmentioning
confidence: 99%
“…Another study revealed that phacoemulsification did not generate aerosols of 10 μm or smaller with continuous power using 80% longitudinal, 100% torsional, or 80% longitudinal setting with HPMC on the surface [ 39 ]. Visible aerosol generation during vitrectomy surgery has been also evaluated using a physical model, although this study did not find evidence of visible aerosol generation during simulated vitrectomy surgery [ 40 ].…”
Section: Risk Of Sars-cov-2 Transmission Through Ophthalmic Procedurementioning
confidence: 99%
“…Previous studies suggest that any aerosol droplets can potentially deliver nucleic acids [ 4 8 ]. The release of aerosol from experimental phacoemulsification was previously reported using real-time imaging or luminol techniques [ 17 21 ]. A porcine-eye mock-up showed that phacoemulsification is a low-risk aerosol-generating procedure, which is also supported by the low transmission risk for SARS-CoV-2 by tears [ 22 24 ].…”
Section: Discussionmentioning
confidence: 99%