2017
DOI: 10.1016/j.scs.2016.11.013
|View full text |Cite
|
Sign up to set email alerts
|

Assessing user thermal sensation in the Aegean region against standards

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 15 publications
1
11
0
Order By: Relevance
“…Despite the mean discrepancy between PMV and OTS being close to zero at neutral votes in Figure 1c, the prediction accuracy of PMV at neutral remains less than half in most cases regardless of ventilation, building and climate types (cases 2 to 11). Surprisingly, in all climates where data was available (cases 12 & 15, 21 & 24 and 30 & 33), we found a higher PMV prediction accuracy for neutrality in NV compared to AC offices.…”
Section: Pmv Prediction Accuracymentioning
confidence: 62%
See 1 more Smart Citation
“…Despite the mean discrepancy between PMV and OTS being close to zero at neutral votes in Figure 1c, the prediction accuracy of PMV at neutral remains less than half in most cases regardless of ventilation, building and climate types (cases 2 to 11). Surprisingly, in all climates where data was available (cases 12 & 15, 21 & 24 and 30 & 33), we found a higher PMV prediction accuracy for neutrality in NV compared to AC offices.…”
Section: Pmv Prediction Accuracymentioning
confidence: 62%
“…The first method graphs the linear relationship between the predicted (PMV or PPD) and observed (thermal sensation or percent of dissatisfied) votes. With this method, the model performance improves as the slope of the regression approaches 1 and the intercept nears 0 [11][12][13]. Along with the slope and intercept, the coefficient of determination (r 2 ) and the error terms between the predicted and observed values are used as metrics of model accuracy.…”
Section: Validation Methods and Accuracy Of The Pmv-ppd Modelmentioning
confidence: 99%
“…In practice, the equation calculated represents the way the occupants of the building actually feel compared with the sensation that was theoretically expected given the indoor monitored conditions. Using such an equation to model the relationship between OMV and AMV values is very common in the literature [26][27][28] as the examined variables appear to be well fitted by linear models displaying high values of coefficient of determination. This linear effect can be also observed in Fig.…”
Section: Fig 3 Generalized Feedback Duration and Effectmentioning
confidence: 99%
“…Since the PMV-PPD model recommends that a narrow temperature range be applied equally across all building types, climatic zones and population, the prediction accuracy of PMV and PPD indices has been questioned by many researchers. Studies conducted in hot and humid climatic conditions prove that the PMV-PPD model tends to over-predict the perceived warmth in the built environment [3][4][5][6]. Furthermore, thermal comfort complaints have been reported in different types of buildings [3,[7][8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%