2023
DOI: 10.1007/s10792-023-02888-8
|View full text |Cite
|
Sign up to set email alerts
|

Assessing the efficacy of four methods established by four parameters in ICL size selection and relevant influencing factors: a prospective cohort study

Chuhao Tang,
Jiawei Chen,
Yiyun Liu
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…[ 32 , 33 ] In recent years, phakic IOL implantation has demonstrated outstanding efficacy and is on the verge of achieving remarkable success in refractive error correction. [ 34 , 35 ] However, complications such as anterior capsule opacity cataracts, pupillary block glaucoma, and pigmentary glaucoma remains a concern. [ 8 , 36 38 ] Complications are more likely to occur because of an improper phakic IOL size.…”
Section: Discussionmentioning
confidence: 99%
“…[ 32 , 33 ] In recent years, phakic IOL implantation has demonstrated outstanding efficacy and is on the verge of achieving remarkable success in refractive error correction. [ 34 , 35 ] However, complications such as anterior capsule opacity cataracts, pupillary block glaucoma, and pigmentary glaucoma remains a concern. [ 8 , 36 38 ] Complications are more likely to occur because of an improper phakic IOL size.…”
Section: Discussionmentioning
confidence: 99%
“…CRL can affect the position and movement of the natural lens and the ICL, excessive CLR can lead to potential complications such as contact between the ICL and the natural lens, which may result in elevated IOP. Therefore, accurate preoperative ocular measurements, such as ACD, white-to-white (WTW) distance, angle-to-angle (ATA) distance, angle Kappa, accommodative amplitude, sulcus-to-sulcus (STS) diameter and anterior segment optical coherence tomography (AS-OCT) are very important for preoperative crystal selection and appropriate postoperative ICL vault prediction ( 22 , 32 , 33 ).…”
Section: Excessive Icl Vaultmentioning
confidence: 99%
“…7 8 Nowadays, some studies have used formula regression methods to analyse the size of ICL. [9][10][11][12][13][14] These studies have incorporated a few parameters, leading to a poor fit in multiple parameter regressions, which does not adequately consider various aspects for predicting the ICL size. Thus, it is necessary to build an accurate ICL selection system.…”
Section: Strengths and Limitations Of This Studymentioning
confidence: 99%
“…However, due to the indirect measurement of eye parameters, differences in the anatomical structure of the anterior segment, and the fact that only four ICL sizes are available for implantation in the market, the patient’s postoperative vaults may be too high or too low 7 8. Nowadays, some studies have used formula regression methods to analyse the size of ICL 9–14. These studies have incorporated a few parameters, leading to a poor fit in multiple parameter regressions, which does not adequately consider various aspects for predicting the ICL size.…”
Section: Introductionmentioning
confidence: 99%