2017
DOI: 10.14366/usg.16022
|View full text |Cite
|
Sign up to set email alerts
|

Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

Abstract: PurposeThe purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands.MethodsVolume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensiona… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 21 publications
0
7
0
1
Order By: Relevance
“…Recent advances in US technology have introduced 3-dimensional (3D) cranial US (3DUS), which acquires complete data sets within the volume of interest using various methods: free-hand acquisition with a tracking system, acquisition with a motor-driven 3D transducer, and acquisition with a 2D matrix array transducer [ 6 ], thereby allowing a comprehensive understanding of anatomical structures and disease entities, as well as the reconstruction of other planes [ 7 ]. Publications have acknowledged the success of 3DUS in the fields of obstetrics and cardiology and the diagnosis of prostate and breast disorders [ 2 , 5 , 7 - 9 ]. Furthermore, the 3DUS technique can enable the almost complete and consistent acquisition of volume data without missing regions, which in turn may improve the diagnostic confidence of interpreters, thereby overcoming the limitations of 2DUS [ 10 ].…”
Section: Introductionmentioning
confidence: 99%
“…Recent advances in US technology have introduced 3-dimensional (3D) cranial US (3DUS), which acquires complete data sets within the volume of interest using various methods: free-hand acquisition with a tracking system, acquisition with a motor-driven 3D transducer, and acquisition with a 2D matrix array transducer [ 6 ], thereby allowing a comprehensive understanding of anatomical structures and disease entities, as well as the reconstruction of other planes [ 7 ]. Publications have acknowledged the success of 3DUS in the fields of obstetrics and cardiology and the diagnosis of prostate and breast disorders [ 2 , 5 , 7 - 9 ]. Furthermore, the 3DUS technique can enable the almost complete and consistent acquisition of volume data without missing regions, which in turn may improve the diagnostic confidence of interpreters, thereby overcoming the limitations of 2DUS [ 10 ].…”
Section: Introductionmentioning
confidence: 99%
“…Measurements in 2-D have been frequently observed to be smaller than 3-D measurements in a variety of other regions. [36][37][38] Regardless of the precise reason, the metric disparity between B-mode and IVUS is an empiric fact that needs to be reckoned with in clinical decision making. Individual laboratories should cross-check the validity of their duplex iliac vein measurements against IVUS or CT venography-based measurements.…”
Section: Caliber Discrepancy Between Ivus and Duplexmentioning
confidence: 99%
“…After surgical excision of the previously localised parathyroid adenoma, the craniocaudal, mediolateral, and anteroposterior diameters were measured, and the volume of the adenoma was calculated as an ellipsoid equation [12,13].…”
Section: Intra-operatory Adenoma Volumementioning
confidence: 99%