2012
DOI: 10.1016/j.ces.2011.10.053
|View full text |Cite
|
Sign up to set email alerts
|

Assessing solids concentration homogeneity in Rushton-agitated slurry reactors using electrical resistance tomography (ERT)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
47
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 54 publications
(48 citation statements)
references
References 19 publications
1
47
0
Order By: Relevance
“…Carletti et al also used ERT to investigate the spatial solids distribution in a stirred tank and they proposed a method to evaluate the solids distribution under different working conditions and geometrical set‐up. Tahvildarian et al and Harrison et al used ERT to study how the working condition, particle size, and particle concentration affected the solids concentration homogeneity in a stirred tank. Positron Emission Particle Tracking is a nonintrusive Lagrangian flow visualization technique that has been used to obtain the full 3D velocity and concentration fields of both the continuous phase and the dispersed phase in opaque mixing equipment .…”
Section: Introductionmentioning
confidence: 99%
“…Carletti et al also used ERT to investigate the spatial solids distribution in a stirred tank and they proposed a method to evaluate the solids distribution under different working conditions and geometrical set‐up. Tahvildarian et al and Harrison et al used ERT to study how the working condition, particle size, and particle concentration affected the solids concentration homogeneity in a stirred tank. Positron Emission Particle Tracking is a nonintrusive Lagrangian flow visualization technique that has been used to obtain the full 3D velocity and concentration fields of both the continuous phase and the dispersed phase in opaque mixing equipment .…”
Section: Introductionmentioning
confidence: 99%
“…Cilliers and his co-workers have developed and applied an ERT system Cilliers et al, 2001) to study foam, in particular the foam density distribution. Cilliers and his co-workers also tested ERT in solidliquid systems (Stevenson et al, 2006;Harrison et al, 2012). Jin et al (2007) studied the Sauter mean bubble size and rise velocity of a gas bubble swarm in a laboratory scale bubble column using ERT.…”
Section: Electrical Resistance Tomography (Ert)mentioning
confidence: 97%
“…[22][23][24][25] The technique has a relatively high temporal resolution, up to few milliseconds, with sufficient spatial resolution of up to 1-3 % of column diameter. [26] The latest development of electrical tomography could capture tomography data up to 1000 frames per second.…”
mentioning
confidence: 99%