Assessing exposure of sediment biota to organic contaminants by thin‐film solid phase extraction

Abstract: Differences in bioavailability among sediments are a source of variability and uncertainty in sediment quality assessment. We present three sets of studies designed to test a thin-film solid phase extraction technique for characterizing the bioavailability of organic chemicals in sediments. Laboratory studies with spiked natural sediments reveal highly reproducible thin-film extractions for chemicals with octanol-water partition coefficients between 10(4.5) and 10(8.5), with 95% equilibration times between 1 a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
23
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(23 citation statements)
references
References 23 publications
0
23
0
Order By: Relevance
“…As highlighted in the review by Lydy et al (this issue), the simple approach of measuring C free using PSMs and then estimating bioaccumulation has been applied successfully in an increasing number of studies, including those for complex petroleum hydrocarbons, PAHs, chlorobenzenes, and PCBs (Kraaij et al ; Barthe et al ; Muijs and Jonker ; Jahnke et al ). The use of passive samplers as an analytical tool to predict bioaccumulation in laboratory studies may provide conservative estimates if uptake on the sampler is faster than the test organism and the test duration is not long enough to attain equilibrium in biota (Meloche et al ).…”
Section: Bioaccumulation Assessmentmentioning
confidence: 99%
“…As highlighted in the review by Lydy et al (this issue), the simple approach of measuring C free using PSMs and then estimating bioaccumulation has been applied successfully in an increasing number of studies, including those for complex petroleum hydrocarbons, PAHs, chlorobenzenes, and PCBs (Kraaij et al ; Barthe et al ; Muijs and Jonker ; Jahnke et al ). The use of passive samplers as an analytical tool to predict bioaccumulation in laboratory studies may provide conservative estimates if uptake on the sampler is faster than the test organism and the test duration is not long enough to attain equilibrium in biota (Meloche et al ).…”
Section: Bioaccumulation Assessmentmentioning
confidence: 99%
“…Glass jars coated with ethylene vinyl acetate co‐polymer have also been used as a passive sampler. Results of equilibration with laboratory‐spiked and field sediments were used to estimate C free as a measure of bioavailability of HOCs (Golding et al , ; Meloche et al ). As with other coatings, ethylene vinyl acetate co‐polymer worked well to estimate the bioavailability of PAHs and PCBs to marine species (Golding et al ; Meloche et al ).…”
Section: Configurations and Materialsmentioning
confidence: 99%
“…A variety of polymers have been employed, including polyethylene, 8−11 polyoxymethylene, 11−14 ethylene vinyl acetate, 15,16 and PDMS. 11,[17][18][19][20][21] The equilibration between the sample and the polymer has mostly been done in the laboratory, but some field applications (generally to sample water) have also been reported.…”
Section: ■ Introductionmentioning
confidence: 99%