2017
DOI: 10.1061/(asce)cf.1943-5509.0000969
|View full text |Cite
|
Sign up to set email alerts
|

Assessing a Retrofitting Method for Existing RC Buildings with Low Seismic Capacity in Turkey

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 27 publications
0
4
0
1
Order By: Relevance
“…Bağıntı (2)'deki sürtünme katsayısı (μ e ), ve A h kesme sürtünme donatısı bağıntı (4) ve bağıntı (5)'deki gibi hesaplanmaktadır. 2 6.9 [91] tarafından önerilen beton modeli kullanılmıştır. Basınç gerinim ve gerilme ilişkisi (9) numaralı bağıntı kullanılarak elde edilmiştir.…”
Section: şEkil 4 -Ts 9967'ye Uygun Inceltilmiş Uçlu Prefabrike Kiriş Donatı Yerleşimi Ve çAtlakunclassified
“…Bağıntı (2)'deki sürtünme katsayısı (μ e ), ve A h kesme sürtünme donatısı bağıntı (4) ve bağıntı (5)'deki gibi hesaplanmaktadır. 2 6.9 [91] tarafından önerilen beton modeli kullanılmıştır. Basınç gerinim ve gerilme ilişkisi (9) numaralı bağıntı kullanılarak elde edilmiştir.…”
Section: şEkil 4 -Ts 9967'ye Uygun Inceltilmiş Uçlu Prefabrike Kiriş Donatı Yerleşimi Ve çAtlakunclassified
“…In the analytical part, the ABAQUS models of 2D frame specimens tested by Korkmaz and Ecemis (2017) were created. The analytical models were created in parallel with the modeling principles performed in the study of Dere (2016) and experimental and analytical results were compared. Failure modes and deformation patterns obtained by experimental and analytical simulation were also compared.…”
Section: Use Of Steel Plate Shear Walls For Lateral Rigiditymentioning
confidence: 99%
“…Korkmaz (2012), Unal (2012) and Bahadir (2012) examined the strengthening of 1/3 scale reinforced concrete test frames with reinforced concrete walls added to the façade. In the analytical study by Dere (2016), finite element models of 2-story and single-span test frames, which had been tested by Korkmaz (2012), were formed in ABAQUS (2020, Computer software, Dassault Systèmes) environment. The experimental and ABAQUS model analysis results were compared and found to be in good agreement.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, damage may occur to structural members. After evaluating the level of damage to structural members, various strengthening techniques can be applied to structural systems [12][13][14][15][16]. Because of some economic or constructional reasons, it is not always possible to rebuild the existing building whose seismic safety has been compromised by seismic action.…”
Section: Introductionmentioning
confidence: 99%