1975
DOI: 10.1002/jps.2600640309
|View full text |Cite
|
Sign up to set email alerts
|

Assay for Acetazolamide in Plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

1977
1977
2015
2015

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(4 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…Bayne et al (6) had a similar problem with their acetazolamide assay. In its absence, the peak height ratio of the drug to the internal standard diminished on successive injections of plasma extract, which may have been due to an accumulation of interfering substances.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Bayne et al (6) had a similar problem with their acetazolamide assay. In its absence, the peak height ratio of the drug to the internal standard diminished on successive injections of plasma extract, which may have been due to an accumulation of interfering substances.…”
Section: Resultsmentioning
confidence: 99%
“…Methods for the quantitation of this drug in biological fluids include measurement of the carbonic anhydrase inhibition (1, a), colorimetry (3,4), electron-capture GLC (5), and high-performance liquid chromatography (HPLC) (6). Methods for the quantitation of this drug in biological fluids include measurement of the carbonic anhydrase inhibition (1, a), colorimetry (3,4), electron-capture GLC (5), and high-performance liquid chromatography (HPLC) (6).…”
mentioning
confidence: 99%
“…It acts on the central nervous system to retard the abnormal, paroxysmal, and excessive discharge from CNS neurons (1). Various methods were reported for its determination either per se or in pharmaceutical preparations and biological fluids including: spectrophotometry (2)(3)(4)(5)(6), HNMR (4), electrochemical methods (7,8), and HPLC (9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27). The British Pharmacopoeia (BP) (28) recommended potentiometric determination of ACM in dimethylformamide using ethanolic solution of sodium hydroxide as a titrant, while the United States Pharmacopoeia (USP) method (29) recommended a spectrophotometric measurement of the acidic solution of the pharmaceutical preparation at 265 nm.…”
Section: Introductionmentioning
confidence: 99%
“…The microgram or nanogram per milliliter concentrations of many drugs found in plasma after therapeutic doses have confined the use of HPLC analysis to drugs having high molar absorptivities at 254 or 280 nm, the wavelengths most frequently used in these detectors (12)(13)(14)(15)(16)(17)(18). UV absorption detectors have been commonly used in HPLC.…”
mentioning
confidence: 99%