Aspects to take into account in the application of mechanical calculation to high-temperature low-sag conductors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
6
3

Relationship

4
5

Authors

Journals

citations
Cited by 23 publications
(28 citation statements)
references
References 7 publications
0
26
0
1
Order By: Relevance
“…The knee-point temperature where the aluminum gets slack should be modeled too. The calculation method used to model the conductor behavior is adapted from sag-tension method developed by some of the authors taking into account the requirements of the HTLS conductors [9][10][11]. This sag-tension model is simplified for the evaluation of the low sag behavior.…”
Section: A Theoretical Modelmentioning
confidence: 99%
“…The knee-point temperature where the aluminum gets slack should be modeled too. The calculation method used to model the conductor behavior is adapted from sag-tension method developed by some of the authors taking into account the requirements of the HTLS conductors [9][10][11]. This sag-tension model is simplified for the evaluation of the low sag behavior.…”
Section: A Theoretical Modelmentioning
confidence: 99%
“…The knee-point temperature where the aluminum gets slack has to be modeled too. The calculation method used to model the conductor behavior is based in a sagtension method developed by some of the authors taking into account the requirements of the HTLS conductors [16][17][18]. Figure 4 shows the theoretical tension-temperature curve of the conductor monitored in the presented example (Fig.…”
Section: B Conductor Evaluationmentioning
confidence: 99%
“…This system, known as TAM System, monitors the mechanical tension, the ambient temperature, the solar radiation and the current intensity. The tension-temperature calibration curve is obtained from mechanical 6 calculation [14][15] and a tension-temperature reference value. The tension-temperature reference value is updated in order to take into account the conductor creep.…”
Section: Conductor Tension Monitoring Systemsmentioning
confidence: 99%
“…The conductor temperature can be measured directly [7][8][9][10] or it can be obtained indirectly from other magnitudes such as the conductor tension [11][12][13][14][15] or the sag [16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%