2013
DOI: 10.1021/ac4027093
|View full text |Cite
|
Sign up to set email alerts
|

Asn3, a Reliable, Robust, and Universal Lock Mass for Improved Accuracy in LC–MS and LC–MS/MS

Abstract: The use of internal calibrants (the so-called lock mass approach) provides much greater accuracy in mass spectrometry based proteomics. However, the polydimethylcyclosiloxane (PCM) peaks commonly used for this purpose are quite unreliable, leading to missing calibrant peaks in spectra and correspondingly lower mass measurement accuracy. Therefore, we here introduce a universally applicable and robust internal calibrant, the tripeptide Asn3. We show that Asn3 is a substantial improvement over PCM both in terms … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 30 publications
0
10
0
Order By: Relevance
“…Intact-mass data were collected by LC-MS analysis on a Thermo Scientific LTQ Orbitrap Velos mass spectrometer without fragmentation. Each fraction was injected twice (two technical replicates), using an AGC target setting of 10 6 , with a maximum fill time of 500 ms. A lock-mass standard (penta-asparagine) was added to the chromatographic buffer for continuous mass calibration 13 (Supplementary Experimental Methods). Three biological replicates were performed, yielding a total of 58 files of mass spectra (in .raw format).…”
Section: Methodsmentioning
confidence: 99%
“…Intact-mass data were collected by LC-MS analysis on a Thermo Scientific LTQ Orbitrap Velos mass spectrometer without fragmentation. Each fraction was injected twice (two technical replicates), using an AGC target setting of 10 6 , with a maximum fill time of 500 ms. A lock-mass standard (penta-asparagine) was added to the chromatographic buffer for continuous mass calibration 13 (Supplementary Experimental Methods). Three biological replicates were performed, yielding a total of 58 files of mass spectra (in .raw format).…”
Section: Methodsmentioning
confidence: 99%
“…MS/MS spectrum data type was set to centroid. The polydimethylcyclosiloxane background ion at 445.12002 was used for internal calibration (lock mass) in addition to the ion at 361.14660 corresponding to a tri-peptide of asparagine that was spikein the MS solvents as described in (Staes et al, 2013). Similar settings were used for the GST pull down and immunoprecipitation experiments.…”
Section: Lc-ms/ms and Data Analysismentioning
confidence: 99%
“…The false discovery rate is expected to drop with improvements to instrument stability, such as the utilization of a lock-mass standard in the chromatographic buffer for continuous mass calibration. 27 …”
Section: Resultsmentioning
confidence: 99%