Asleep Robot-Assisted Surgery for the Implantation of Subthalamic Electrodes Provides the Same Clinical Improvement and Therapeutic Window as Awake Surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
21
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(24 citation statements)
references
References 35 publications
2
21
0
Order By: Relevance
“…Interestingly, on a phantom study, Lefranc et al showed that registration with CT scan or 3D‐fp‐CT‐scan provided the best results in terms of accuracy. At the target, the accuracy was 0.3 mm with CT scan and 3D‐fp‐CT‐scan vs 1.59 mm with 3T‐MRI . In our procedure, surgical planning is performed with MRI and CT scan, and a 3D‐fp‐CT‐scan with bone screws is performed the day of the surgery.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Interestingly, on a phantom study, Lefranc et al showed that registration with CT scan or 3D‐fp‐CT‐scan provided the best results in terms of accuracy. At the target, the accuracy was 0.3 mm with CT scan and 3D‐fp‐CT‐scan vs 1.59 mm with 3T‐MRI . In our procedure, surgical planning is performed with MRI and CT scan, and a 3D‐fp‐CT‐scan with bone screws is performed the day of the surgery.…”
Section: Discussionmentioning
confidence: 99%
“…For biopsy (except pineal lesion and some brainstem lesion), a non‐invasive registration (surface laser registration) is used. In clinical application, Lefranc et al showed that mean accuracy was equal to 0.42 mm when the procedure included 3D‐fp‐CT‐scan imaging and invasive bone fiducial registration compared with 1.22 mm when surface recognition is used.…”
Section: Discussionmentioning
confidence: 99%
“…In the short term, the UPDRS III score in the “off‐drug, on‐stim” condition fell to a similar extent in the LA and GA groups (by 40.3% and 49%, respectively, p = 0.336). Therefore, they concluded that asleep robot‐assisted implantation of STN‐DBS electrodes (with accurate identification of the STN and positioning of the DBS lead) produced the same motor results and therapeutic window as awake surgery .…”
Section: Clinical Outcomesmentioning
confidence: 99%
“…Almost half of our cohort expressed this fear. Discussing the option of DBS implantation under general anesthesia, which has been shown to be as efficacious as its awake counterpart (35)(36)(37)(38)(39)(40), may reduce this apprehension and thus help reduce the aforementioned under-utilization of DBS.…”
Section: Timing Of Dbs Surgerymentioning
confidence: 99%