2007
DOI: 10.1021/ac0713508
|View full text |Cite
|
Sign up to set email alerts
|

Artificial Neural Network Study of Whole-Cell Bacterial Bioreporter Response Determined Using Fluorescence Flow Cytometry

Abstract: Genetically engineered bioreporters are an excellent complement to traditional methods of chemical analysis. The application of fluorescence flow cytometry to detection of bioreporter response enables rapid and efficient characterization of bacterial bioreporter population response on a single-cell basis. In the present study, intrapopulation response variability was used to obtain higher analytical sensitivity and precision. We have analyzed flow cytometric data for an arsenic-sensitive bacterial bioreporter … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 23 publications
(34 reference statements)
0
10
0
Order By: Relevance
“…The VITOTOX ۚ test has been employed for genotoxicity assessment of several drugs during the early phases of drugs development . GenoTox uses the colicin D gene cda (a constituent of the ColD plasmid) and gfp as a report gene . The signal green fluorescent was measured using flow cytometry to improve the overall sensitivity of the fluorescent biosensors.…”
Section: Medical Applications Of Biosensorsmentioning
confidence: 99%
“…The VITOTOX ۚ test has been employed for genotoxicity assessment of several drugs during the early phases of drugs development . GenoTox uses the colicin D gene cda (a constituent of the ColD plasmid) and gfp as a report gene . The signal green fluorescent was measured using flow cytometry to improve the overall sensitivity of the fluorescent biosensors.…”
Section: Medical Applications Of Biosensorsmentioning
confidence: 99%
“…As with, for instance, linear regression, a test statistic (referred to in this case as vigilance) is used to delineate the boundary between similar and dissimilar signatures. Further details concerning calculation of Euclidian distance and use of vigilance can be found in Busam et al (2007).…”
Section: Calculationmentioning
confidence: 99%
“…Acute toxicity, LM Safe dilution multiplicity, SM Chronic toxicity, LM developed for biological activity testing at all stages of the pharmaceutical technology: from the stage of synthesis and isolation of a substance to production of a new pharmaceutical preparation [26][27][28][29][30]. These biosensors can be used in pharmaceutics for functional screening at the stage of drug design and discovery [31] and for predictive screening at the stage of planning the targeted synthesis and determination of the mechanism of action of the biologically active substance [32], and for toxicity predictions over a wide concentration range without animal experiments [33,34].…”
Section: Biosensor Screening At the Stage Of Drug Developmentmentioning
confidence: 99%