2011
DOI: 10.1007/s00405-011-1719-3
|View full text |Cite
|
Sign up to set email alerts
|

Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT)

Abstract: Until now more than 250,000 cochlea implantations have been performed worldwide. The surgical procedure is well standardized. A discussion about the kind of postoperative radiological control has started since cone beam tomography (CBT) has been established in ENT and hearing preservation operations have come more into the focus. Further research has been concentrated on the role of CBT and the insertion of the basal turn. The aim of this study was to look for the possibilities of CBT and deep insertion. The s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
18
0
2

Year Published

2012
2012
2018
2018

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 35 publications
(22 citation statements)
references
References 23 publications
2
18
0
2
Order By: Relevance
“…Furthermore, CBCT has reduced radiation exposure compared with conventional multislice CT imaging [Cushing et al, 2012;Kurzweg et al, 2010]. The imaging resolution is, however, insufficient for the assessment of intracochlear trauma, and the radiologically measured electrode array diameter is exaggerated due to imaging artifacts [Güldner et al, 2012]. We observed that the CBCT scans provided a sufficient image resolution and quality for estimation of the implanted scala in all cases imaged ( table 1 ).…”
Section: Discussionmentioning
confidence: 67%
“…Furthermore, CBCT has reduced radiation exposure compared with conventional multislice CT imaging [Cushing et al, 2012;Kurzweg et al, 2010]. The imaging resolution is, however, insufficient for the assessment of intracochlear trauma, and the radiologically measured electrode array diameter is exaggerated due to imaging artifacts [Güldner et al, 2012]. We observed that the CBCT scans provided a sufficient image resolution and quality for estimation of the implanted scala in all cases imaged ( table 1 ).…”
Section: Discussionmentioning
confidence: 67%
“…The use of cone‐beam CT for the imaging of the head and neck, especially at the anterior and lateral skull base, has been described before . Cone‐beam CT is also a useful tool for the imaging of cochlear implants for quality control and for detecting the intracochlear position of the electrode . Controversy still exists regarding the dosage of cone‐beam CT in comparison with conventional CT for the imaging of the anterior and lateral skull base.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, an intraoperative cone‐beam computed tomography (CT) or conventional CT is currently considered the best solution. Intraoperative imaging in ENT surgery is presently dependent on cone‐beam CT, because of lower radiation exposure and lower artefacts . The use of imaging along with VSB has been limited.…”
mentioning
confidence: 99%
“…The images do not enable evaluation of the atraumatic nature of the implantation or the preservation of residual hearing. The recent development of the Cone Beam provides new information, and the advantages of this technique in evaluating cochlear trauma are currently being verified in histological samples and in patients [4,8,9].…”
Section: D Micro-ct Scanmentioning
confidence: 99%