2002
DOI: 10.1177/107110070202300203
|View full text |Cite
|
Sign up to set email alerts
|

Arthrodesis of the First Metatarsophalangeal Joint: A Biomechanical Study Comparing Memory Compression Staples, Cannulated Screws, and a Dorsal Plate

Abstract: Arthrodesis of the first metatarsophalangeal joint of 21 matched pairs of cadaver toes was performed in order to compare the strength of three methods of internal fixation: 1. two crossed cannulated screws, 2. a dorsal plate with an oblique 0.062 K-wire, and 3. two compression staples with an oblique 0.062 K-wire. Biomechanical testing with plantar force was carried out, and gapping across the fusion site was measured. Stiffness, load to 1-mm displacement, and force to failure was determined for each specimen.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
35
0
3

Year Published

2009
2009
2020
2020

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 71 publications
(40 citation statements)
references
References 15 publications
2
35
0
3
Order By: Relevance
“…SMA staples are often utilized clinically as fixation-compression devices for osteotomies, arthrodeses and fracture repairs especially of short bones, facial bones and the distal extremities (Choudhary et al 2004; Laster et al 2001; Neufeld et al 2002; Rethnam et al 2009). Yang et al (1987) reviewed 51 cases where SMA staples were first used as an internal fixation device for a range of orthopaedic procedures and described good bone union and functional recovery in the 45 cases that were followed up.…”
Section: Introductionmentioning
confidence: 99%
“…SMA staples are often utilized clinically as fixation-compression devices for osteotomies, arthrodeses and fracture repairs especially of short bones, facial bones and the distal extremities (Choudhary et al 2004; Laster et al 2001; Neufeld et al 2002; Rethnam et al 2009). Yang et al (1987) reviewed 51 cases where SMA staples were first used as an internal fixation device for a range of orthopaedic procedures and described good bone union and functional recovery in the 45 cases that were followed up.…”
Section: Introductionmentioning
confidence: 99%
“…A complex plantar dissection necessary to improve the stability by a plantar plate placement [26] was not necessary. Test models described in literature often use feet disarticulated in the ankle, arranged in an unphysiological position, measuring only translational forces or rely on synthetic bone [25, 27-29]. In some studies the locking plate lacked the possibility of interfragmentary compression and three - dimensional aspects were not taken into consideration in contrast to our study [30, 31].…”
Section: Discussionmentioning
confidence: 99%
“…Artrodez tedavisi uygulanırken Kischner telinden plakvida birlikteliğine kadar birçok materyal tercih edilmiştir (13)(14)(15)(16)(17)(18)(19). Çoklu Kischner teli ile tespit sonrası implantın çıkarılması için ilave cerrahi gereksinimi ve yüksek kaynamama oranı gibi dezavantajlar bildirilmiştir (13).…”
Section: Discussionunclassified
“…Ayrıca gergi bandının vida uygulanmasına nispeten altı kez daha instabil olduğu gösterilmiştir (16). Staple kullanımı ile kabul edilebilir kaynama oranı bildirilmekle birlikte biyomekanik olarak diğer yöntemlere göre daha instabil olduğu gösterilmiştir (18). Birinci MTF eklem artrodezinde vida kullanımı sıklıkla tercih edilen tespit yöntemidir.…”
Section: Discussionunclassified