2011
DOI: 10.1259/dmfr/30642039
|View full text |Cite
|
Sign up to set email alerts
|

Artefacts in CBCT: a review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
706
2
58

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 782 publications
(772 citation statements)
references
References 43 publications
6
706
2
58
Order By: Relevance
“…15,16 Utilizing high-resolution scan modes increases spatial resolution while increasing image noise at very thin slice thicknesses, and it additionally exacerbates the influence of metal streak artefacts in the image and therefore could result in a poor image. 17 Several reconstruction algorithms and techniques are currently under investigation and have been partially implemented by several manufacturers to improve image quality at low scan modes.…”
Section: Discussionmentioning
confidence: 99%
“…15,16 Utilizing high-resolution scan modes increases spatial resolution while increasing image noise at very thin slice thicknesses, and it additionally exacerbates the influence of metal streak artefacts in the image and therefore could result in a poor image. 17 Several reconstruction algorithms and techniques are currently under investigation and have been partially implemented by several manufacturers to improve image quality at low scan modes.…”
Section: Discussionmentioning
confidence: 99%
“…11 Hasta hareketleri, her bir imaj çok kısa süre-lerde elde edildiği için bütün imajlarda büyük keskinlik problemi oluşturmayabilir. Fakat değişik derecelerde bulanıklıklar oluşturarak imaj rekonsrüksiyonunu direkt olarak etkiler.…”
Section: Hasta İle İlgi̇li̇ Artefaktlarunclassified
“…Küçük voksel seçimi bu durumun etkisini azaltabilir. 8,11,13 4.2. Eksik örnekleme(Undersampling): İmaj rekonstrüksiyonu için az sayıda temel projeksiyon oluşturulduğunda bu artefakt meydana gelir.…”
Section: Koni̇k Işin İle İlgi̇li̇ Artefaktlarunclassified
See 1 more Smart Citation
“…For the PMMA section, it can be seen that the cupping artefact is quite strong, with .50% decrease in voxel value from the periphery to the centre of the FOV. This artefact is mainly owing to scatter and the beam hardening effect [18]. The bowtie filtration limits such artefact and flattens the profile, lowering peripheral voxel values by ;25% and raising voxel values in the inner half by ;10%.…”
Section: Image Qualitymentioning
confidence: 99%