2020
DOI: 10.1088/1748-605x/abb25a
|View full text |Cite
|
Sign up to set email alerts
|

Arsenic trioxide-eluting electrospun nanofiber-covered self-expandable metallic stent reduces granulation tissue hyperplasia in rabbit trachea

Abstract: Stent-related granulation tissue hyperplasia is a major complication that limits the application of stents in airways. In this study, an arsenic trioxide-eluting electrospun nanofiber-covered self-expandable metallic stent (ATO-NFCS) was developed. Poly-L-lactide-caprolactone (PLCL) was selected as the drug-carrying polymer. Stents with two different ATO contents (0.4% ATO/PLCL and 1.2% ATO/PLCL) were fabricated. The in vitro release in simulated airway fluid suggested that the total ATO release time was 1 d. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 13 publications
(16 citation statements)
references
References 37 publications
0
16
0
Order By: Relevance
“…Hybrid stents are often referred to as a “covered” or “coated” stents. In our review, 19 studies employed hybrid stents as outlined in Tables I–III 4,20,27,36–51 . This diverse group of stents utilized a stainless steel or nitinol framework coated with polyurethane (n = 7), 20,27,40–42,44,48 silicone (n = 3), 39,49,50 expanded polytetrafluoroethylene (n = 1), 49 polyester (n = 1), 49 polypropylene (n = 1), 49 unspecified material (n = 4), 4,38,43,45 and drug‐eluting polymers (n = 3) 46,47,51 .…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Hybrid stents are often referred to as a “covered” or “coated” stents. In our review, 19 studies employed hybrid stents as outlined in Tables I–III 4,20,27,36–51 . This diverse group of stents utilized a stainless steel or nitinol framework coated with polyurethane (n = 7), 20,27,40–42,44,48 silicone (n = 3), 39,49,50 expanded polytetrafluoroethylene (n = 1), 49 polyester (n = 1), 49 polypropylene (n = 1), 49 unspecified material (n = 4), 4,38,43,45 and drug‐eluting polymers (n = 3) 46,47,51 .…”
Section: Resultsmentioning
confidence: 99%
“…Nineteen studies utilized different polymers as stent materials 15,46,47,51–66 . Only one of these represented a human clinical study where polydioxanone (PDS) stents were used in four patients 64 .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The electrospinning parameters and drug content of the fiber films were as recommended in previous reports [ [23] , [24] , [25] , [26] ]. In brief, 1.25 g of PCL was first dissolved in 10 mL of hexafluoroisopropanol (HFIP) to prepare the PCL solution.…”
Section: Methodsmentioning
confidence: 99%