Arrhythmia ECG Noise Reduction by Ensemble Empirical Mode Decomposition

Abstract: A novel noise filtering algorithm based on ensemble empirical mode decomposition (EEMD) is proposed to remove artifacts in electrocardiogram (ECG) traces. Three noise patterns with different power—50 Hz, EMG, and base line wander – were embedded into simulated and real ECG signals. Traditional IIR filter, Wiener filter, empirical mode decomposition (EMD) and EEMD were used to compare filtering performance. Mean square error between clean and filtered ECGs was used as filtering performance indexes. Results show… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
78
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 168 publications
(80 citation statements)
references
References 21 publications
(26 reference statements)
1
78
0
1
Order By: Relevance
“…In the past, some interesting EMD procedures have been proposed to automatically select and classify the IMFs of interest. They can be divided into two categories: (i) methods based on low-pass filtering [44][45][46] and (ii) methods based on thresholding filtering [47,48]. EMD based on low-pass filtering considers that the IMFs are decomposed into two sets: the first set of IMFs represents only the signal of interest and the second set stands for the noise and artifacts.…”
Section: Selection Of Components Of Interestmentioning
confidence: 99%
“…In the past, some interesting EMD procedures have been proposed to automatically select and classify the IMFs of interest. They can be divided into two categories: (i) methods based on low-pass filtering [44][45][46] and (ii) methods based on thresholding filtering [47,48]. EMD based on low-pass filtering considers that the IMFs are decomposed into two sets: the first set of IMFs represents only the signal of interest and the second set stands for the noise and artifacts.…”
Section: Selection Of Components Of Interestmentioning
confidence: 99%
“…3.Here other than white Gaussian is also added to ECG signal to check the performance of EEMD algorithm. Three different patterns of added noise are [4] …”
Section: Experiments and Resultsmentioning
confidence: 99%
“…The electrocardiogram (ECG) has been widely used for diagnosis purposes of heart diseases [5]. Good quality ECG is utilized by the physicians for interpretation and identification of physiological and pathological phenomena.…”
Section: Ecg Signalmentioning
confidence: 99%