2019
DOI: 10.1177/1129729819848918
|View full text |Cite
|
Sign up to set email alerts
|

Arm position and collapsibility of infraclavicular axillary vein during voluntary breathing: An ultrasound-guided observational study

Abstract: Background: Arm abduction influences cross-sectional area of the infraclavicular axillary vein, yet the effect of arm abduction on collapsibility of the vein has not been quantified. Decrease in collapsibility of the axillary vein can enable successful cannulation and can decrease injury to underlying vital structures. Methods: The infraclavicular axillary vein was scanned in 70 patients close to the clavicle with a high-frequency linear transducer in arm adducted position (Point A), after arm abduction at the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…Arm abduction moves the lateral end of the clavicle cephalad over the rib cage, 15 and this exposes the 2-3 cm proximal length of IAV, otherwise obscured by the post acoustic shadow of the clavicle when the arm is in a neutral position. 8,15 This proximal portion of the IAV is also less collapsible because it is tethered to the clavipectoral fascia enclosing the subclavius muscle. 16 As the IAV ascends over the rib cage it receives the cephalic venous drainage and at its proximal end, becomes more prominent and superficial before disappearing under the clavicle.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Arm abduction moves the lateral end of the clavicle cephalad over the rib cage, 15 and this exposes the 2-3 cm proximal length of IAV, otherwise obscured by the post acoustic shadow of the clavicle when the arm is in a neutral position. 8,15 This proximal portion of the IAV is also less collapsible because it is tethered to the clavipectoral fascia enclosing the subclavius muscle. 16 As the IAV ascends over the rib cage it receives the cephalic venous drainage and at its proximal end, becomes more prominent and superficial before disappearing under the clavicle.…”
Section: Discussionmentioning
confidence: 99%
“…3,4 Attempts to cannulate the vein with marked collapsibility can increase the number of needle punctures and result in serious complications such as pneumothorax and arterial puncture in a non-compressible region. The Trendelenburg position, 5 retracted shoulder position 6 and arm abduction [7][8][9] have been evaluated for their ability to improve venous diameter and decrease collapsibility. Among these, arm abduction was shown to significantly decrease the collapsibility index and increase the cross-sectional area and circumference of the vein during spontaneous breathing.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Thanks to the direct visualization of the targeted vein without the use of nephrotoxic iodinated contrast media, USGAVA minimizes exposure to ionizing radiation during fluoroscopy [29,30]. Despite USGAVA proving to be a reliable method for CIED implantation, the respiratory variation in AV size during tidal breathing, which can lead to complete venous collapse [31,32], represents a significant challenge for successful vein puncture and cannulation. Asking the patient to hold a forced expiration for a few seconds, as prescribed by the Valsalva maneuver, has the potential to address these challenges.…”
Section: Introductionmentioning
confidence: 99%
“…[ 3 ] Conversely, arm abduction by 90° elevates the lateral end of the clavicle by 3.5 cm, exposing approximately 3 cm of the proximal IAV. [ 4 ] This medial segment of the IAV is larger and less collapsible, facilitating high first-pass success compared to the neutral arm position. Hence, we propose arm abduction as the optimal position for ultrasound-guided IAV cannulation.…”
mentioning