2003
DOI: 10.1111/j.1464-410x.2004.04568.x
|View full text |Cite
|
Sign up to set email alerts
|

Are new‐generation flexible ureteroscopes better than their predecessors?

Abstract: endoscopic tools were assessed. Specifications, purchase prices and repair costs were obtained from each manufacturer. The field of view and screen image size of each ureteroscope were also compared. RESULTSThe ACMI DUR-8 Elite and the Storz 11278AU had improvements of 79 ∞ and 144 ∞ , respectively, from their respective older models. Although the tip deflection of all ureteroscopes was compromised by inserting different endoscopic tools, these new instruments were less affected. With a 3 F basket inside the w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2005
2005
2018
2018

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…They maintain a high degree of flection even after introduction of instruments to secure access to the lower renal calix. [4][5][6] The aim of this study was to evaluate one of these new instruments in an in vitro, ex vivo, and clinical approach for durability and clinical use and to compare this ureteroscope with a standard flexible ureteroscope.…”
Section: Introductionmentioning
confidence: 99%
“…They maintain a high degree of flection even after introduction of instruments to secure access to the lower renal calix. [4][5][6] The aim of this study was to evaluate one of these new instruments in an in vitro, ex vivo, and clinical approach for durability and clinical use and to compare this ureteroscope with a standard flexible ureteroscope.…”
Section: Introductionmentioning
confidence: 99%
“…13 The Flex-X (Karl Storz, Culver City, CA) and the DUR-8 Elite (ACMI, Southborough, MA) represent the latest generation of flexible ureteroscopes, distinguished by the advantage of an increased maximum angle of deflection, maintained even after the introduction of stone management tools. 2,13,14 So, the loss of maximal active deflection is reduced during calculi extraction procedures. 2,14,15 We must also mention the fact that the new miniaturized nitinol stone extraction instruments and lithotripter probes decrease the loss of maximal deflection.…”
Section: Discussionmentioning
confidence: 97%
“…There is no available report, however, to demonstrate the superiority of a new flexible ureterorenoscope over another one. 2,3,5,8,10,14,15 Today, the ideal flexible ureterorenoscope is probably not available, but because of past improvements, in terms of lower-pole access and lower-pole stone management, the scope makes the difference.…”
Section: Discussionmentioning
confidence: 97%