Arc flash fault detection in wind farm collection feeders based on current waveform analysis

Abstract: High impedance faults (HIFs) are easy to occur in collective feeders in wind farms and may cause the cascading of wind generators tripping. This kind of faults is difficult to be detected by traditional relay or fuse due to the limited fault current values and the situation is worse in wind farms. The mostly adopted HIF detection algorithms are based on the 3 rd harmonic characteristic of the fault zero-sequence currents, whereas these 3 rd harmonics are very easy to be polluted by wind power back-to-back conv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…ΔZ im = ΔZ in ΔZ jm = ΔZ jn ΔZ km = ΔZ kn (24) where i, j, and k are respectively upstream, downstream and parallel nodes of m-n. The visual representation of Laws 5 to 7 is shown in Figure 7.…”
Section: Addition Of Link-branchesmentioning
confidence: 99%
See 1 more Smart Citation
“…ΔZ im = ΔZ in ΔZ jm = ΔZ jn ΔZ km = ΔZ kn (24) where i, j, and k are respectively upstream, downstream and parallel nodes of m-n. The visual representation of Laws 5 to 7 is shown in Figure 7.…”
Section: Addition Of Link-branchesmentioning
confidence: 99%
“…In practical engineering, the grounding method through resistance is widely adopted [20]. Therefore, an effective and complete current flow path can be formed when asymmetric phase‐to‐ground faults occur, which makes the zero‐sequence characteristic of wind farms more significant and thus enables that some protection and fault diagnosis schemes in wind farms can be achieved based on zero‐sequence current [23, 24]. In addition, in order to isolate the harmonic and zero‐sequence current from WTGs, BTs at WTGs adopt the delta‐grounded‐wye winding configuration as shown in Figure 1 [23, 25].…”
Section: Typical Structure Of Onshore Wind Farmsmentioning
confidence: 99%
“…3. Back-to-back converters of a wind turbine [16]. Supercapacitors or ultra-capacitors give the possibility of oversizing the DC link.…”
Section: Grid-following With Inertia Emulationmentioning
confidence: 99%
“…Nevertheless, the arcing ignition caused by an HIF is a safety hazard [4,6]. Moreover, undetected HIFs have been reported to cause instability of renewable energy systems [7]. As a result, reliably detecting and clearing HIFs in a timely manner are crucial to ensure the safety of personnel and maintain the power system integrity [4][5][6].…”
Section: Introductionmentioning
confidence: 99%