2006
DOI: 10.1016/j.chroma.2006.01.068
|View full text |Cite
|
Sign up to set email alerts
|

Aqueous chromatography system using pH- and temperature-responsive stationary phase with ion-exchange groups

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
37
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 57 publications
(37 citation statements)
references
References 24 publications
0
37
0
Order By: Relevance
“…This has already been illustrated in the pioneering work on TR-LC by the group of Okana et al [4][5][6] and in many applications including the analysis of small molecules, pharmaceuticals and biomolecules [7,8]. Columns containing copolymers of NIPAAm with hydrophobic [5][6][7]9], ionic [8,10], and affinity ligands [11] have extended the applicability range of TR-LC.…”
Section: Introductionmentioning
confidence: 89%
“…This has already been illustrated in the pioneering work on TR-LC by the group of Okana et al [4][5][6] and in many applications including the analysis of small molecules, pharmaceuticals and biomolecules [7,8]. Columns containing copolymers of NIPAAm with hydrophobic [5][6][7]9], ionic [8,10], and affinity ligands [11] have extended the applicability range of TR-LC.…”
Section: Introductionmentioning
confidence: 89%
“…While the HCO elution peak remained unchanged, the retention time of TES decreased from 30.9 to 19.9 min and the elution peak became sharper. In conventional chromatography, elution is modulated by the addition of organic solvents or increasing the salt concentration in the mobile phase, or by heating/cooling the entire mobile phase [40][41][42]. The proposed AMF system instead relies on the self-heating of the stationary phase, which is controlled by switching the AMF on and off.…”
Section: Amf-induced Switchable Elution Control Of Steroidsmentioning
confidence: 99%
“…Because this type of ionic copolymer is known to shift its pKa in response to temperature changes, the silica beads exhibited simultaneous changes in wettability and charge density under thermal stimuli. These systems can be cost-effective and environmentally friendly, because the elution profiles can be controlled using only an aqueous solution as a mobile phase; however, their performance is adversely affected by the heating/cooling process of the entire mobile phase [40][41][42].…”
Section: Introductionmentioning
confidence: 99%
“…In 2006, they developed a new HPLC method for the analysis of non-steroidal antiinflammatory drugs such as ibuprofen and ketoprofen (6). They designed a new temperature/pH sensitive stationary phase by modifying aminopropyl silica beads with a NIPAM-based nanoparticle with two incorporated co-monomers: butyl methacrylate (BMA) and N,Ndimethylaminopropylacrylamide (DMAPAAm).…”
Section: Introductionmentioning
confidence: 99%
“…The latter can be used in many applications such as the control of cell and protein adhesion, (1-4) and bioseparation (5,6).…”
Section: Introductionmentioning
confidence: 99%