Approaching a Million-Fold Sensitivity Increase in Capillary Electrophoresis with Direct Ultraviolet Detection:  Cation-Selective Exhaustive Injection and Sweeping

Abstract: A novel method that combines two on-line concentration techniques in capillary electrophoresis (CE), namely, sample stacking with electrokinetic injection (field-enhanced sample injection, FESI) and sweeping, afforded the detection of positively chargeable analytes in parts per trillion (ppt) levels. The main idea is to selectively introduce by FESI as many molecules of cationic analytes as possible from a very dilute sample solution and focus the resulting zone by sweeping. Limit of detection values (signal-t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

6
248
0

Year Published

2000
2000
2011
2011

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 316 publications
(254 citation statements)
references
References 27 publications
(51 reference statements)
6
248
0
Order By: Relevance
“…In these conditions, approximately 4.6 nL of sample solution (assumed viscosity of 1 cP) is introduced into the capillary during the injection. SEF values achieved by the integration of an FESI preconcentration step were then calculated as follows for six different proteins [35]: SEF ¼ peak parameters obtained withpreconcentrain peak parameters obtained without preconcentration…”
Section: Sensitivity and Detection Limitmentioning
confidence: 99%
“…In these conditions, approximately 4.6 nL of sample solution (assumed viscosity of 1 cP) is introduced into the capillary during the injection. SEF values achieved by the integration of an FESI preconcentration step were then calculated as follows for six different proteins [35]: SEF ¼ peak parameters obtained withpreconcentrain peak parameters obtained without preconcentration…”
Section: Sensitivity and Detection Limitmentioning
confidence: 99%
“…However, some of the described methodologies may be used in combination to reach higher SEFs. For example, FESI has been successfully combined with sweeping a few years ago [19]. In that case, extremely high SEFs (between 550,000 and 900,000) have been obtained for 1-naphthylamine and laudanosine, respectively.…”
Section: Introductionmentioning
confidence: 99%
“…Sweeping is representative of this group [5]. Among them, sample stacking and sweeping are most frequently used in MEKC [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24].…”
Section: Introductionmentioning
confidence: 99%
“…Sweeping is defined as a phenomenon where analytes are picked up and accumulated by the pseudostationary phase (micelles [5,[19][20][21][22] or other complexation additives [23,24]) that penetrates the sample zone. It occurs when the sample matrix is void of charged carrier phase, and the sample matrix may have a higher, similar, or lower conductivity compared with the BGE [19][20][21][22][23]31]. Concentration factors of up to 5000 have been reported for some neutral analytes by sweeping long sample zones with SDS in CE [5].…”
Section: Introductionmentioning
confidence: 99%